Instruction for use and installation
RBG 80 / RBG 120/ RBG 200 / RBG 30
USE
Description of the appliance
Gas rotisseries are designed for roasting poultry, game, joints, etc. using infrared radiation
(1050°C). They are available in 4 models (8 to 30 chickens capacity) and are fitted with a
drip tray.
These appliances are for professional use and must therefore be used by qualified personnel.
They must be installed in accordance with current regulations by a qualified installer and in a
sufficiently well ventilated location.
The identification plate is located on the back of the appliance.
Dimensions and capacity
Appliance
Dimensions
RBG 80
940x445x760mm
RBG 120
940x445x955mm
RBG 200
940x445x1250mm
RBG 30
1345x480x1285mm 120 Kg
Technical data
Appliance
RBG 80
RBG 120
RBG 200
RBG 30
Weight
Number of
Capacity
Spits
(no. Of chickens)
30 Kgs
2
40 Kgs
3
72 Kg
5
5
Heat
Number of radiant
output
Burners
11kW
2
16.5kW
3
27.5 kw
5
38 kw
10
Operation
The appliances are fitted with 2 to 5 motors which each drive a spit.
Lighting :
Press the knob and turn it on the star position
Place a flame close to the pilot light or the burner
Keep the knob pressed in for about 5 seconds
The pilot light or the burner will then remain lit
Turn the knob on the big flame position
A thermocouple cuts off the gas supply if one of the radiant burners goes out.
It is recommended to turn off the burner when the spit support is empty, to avoid a high
temperature on the door.
Care and maintenance
Your appliance should be cleaned regularly using a damp sponge.
Do not clean your appliance under running water: water entering the system might damage
it.
For better and long lasting performance, regular checking carried out by qualified installer
are recommended.
Your appliance can operate on the various types of liquid petroleum gas. To change from
one gas to another requires the intervention of qualified installer.
Installation
8
12
The appliance must be installed in accordance with current regulations in a sufficiently
20
well ventilated location.
30
The fresh airflow required providing air for combustion is:
RBG 80
RBG 120
RBG 200
RBG 30
NB:
The side panels of your appliance must not be placed next to a wall or partition
made from combustible material; otherwise, they must be covered in an effective heat
insulating material.
A distance of 30cm from the partition is deemed sufficient.
22m3/h
33m3/h
55 m3/h
76 m3/h