Quick operation guide
After power-up or after 2 minutes of in-
activity the initial screen will appear, this
shows the current status of the lifter (level
0 of the menu).
If the Showlift presents any of the fo-
llowing cases this status screen will chan-
ge depending on the situation, showing
the corresponding information.
1. PARTIAL COUNTER EXCEEDED
If the tower exceeds the 50,000m run in its
partial meter counter, the technical servi-
ce of the supplier should review the belts
and moving parts, so the status screen
will show the following information:
CHECK BELTS AND
MOVING PARTS

2. EMERGENCY STOP

If the lifter has the emergency stop ac-
tivated it is because the red mushroom
button is pressed. The status screen will
show the following information:
EMCY STOP P: 001
CHECK EMGY SW
3. LEGS NOT INSTALLED CORRECTLY
If the tower does not have correctly insta-
lled one of its legs in working position, it
will not work and therefore the following
information will be displayed in the status
screen:
LEGS STOP P:001
CHECK LEGS POS
PRO LIFTS S.L.
4. DEAD MAN SWITCH
If the lifter has the dead man switch op-
tion mode activated and it is not working,
the display will show the following infor-
mation:
5. DRIVER ERROR
If the display shows this error, the user
has to reset the tower. If the display still
shows the same error, the user has to
press the emergency stop button and res-
tart the lifter after 15 seconds.
If this error continues happening the lifter
has to be reviewed as soon as posible by
the technical service of the supplier, as
this error can not be fixed by the user.
In this case, the lifter will not work and the
following information will be displayed:
If the display does not show any of these
status messages, it will start by showing
the following information:
Before using the Showlift It is highly re-
commended to check the surroundings to
make sure there will be no impact on the
height.
The lifter will only start working if the
user presses the central button "En-
ter".
Depósito legal y copyright 2018. Todos los derechos reservados.
ENGLISH
DEAD STOP P:001
CHECK D MAN SW
DRIVER ERROR
RESET MAINS
CHECK ENV & HIT
ENTER TO PWR UP
9