Cebora Mono Star MIG 1620/M synergic Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
This operation always returns us to the previous display
page (PROCESS PARAMS).
• Spot and pause time (Spot).
If we select the spot ON time, the Spot Time function
appears on the display screen. If we select this, we
can adjust it from 0.3 to 25 seconds by means of the
adjustment bar. Besides this function, the display screen
also shows Pause Time. If we select this, by means
of the adjustment bar, we can regulate the pause time
between one welding point or section and another. The
pause time varies between 0 (OFF) and 5 seconds.
To access the Spot Time and Pause Time functions,
press the knob B for less than 2 seconds. Adjustment
is always made by means of the knob B. To confirm,
simply press it for less than 2 seconds. Once the
choice has been confirmed, return is always made to
the display page (PROCESS PARAMS).
• Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the figure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob B for less
than 2 seconds.
12
• AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive figure corresponds to
greater wire burning.
Default is Auto.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob B for less
than 2 seconds.
• Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set
for welding, before the wire touches the piece to be
welded.
This adjustment is important to always obtain good
starts.
Default is Auto.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob B for less
than 2 seconds.
• Options LOCK
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A will show a serial number SN and 8 zeros.
The purpose of this function is to unlock the blocked
synergic curves.
To unlock the curves, instead of the zeros, an
alphanumeric code must be entered. This must be
requested from your dealer, after indicating the serial
number SN.
Once the code has been obtained, simply enter it in
place of the zeros, Each letter or figure entered must be
confirmed by briefly pressing the knob B. After entering
the code, by pressing the knob B for more than 2
seconds, all the curves are unlocked and the display
screen A shows UNLOCK alongside the Options
function.

Publicidad

Tabla de contenido
loading

Tabla de contenido