3. Rating plate identification
Type :
Year:
*the sign -EX indicate the ATEX certificated pumps
1
1 European Parliament and Council Regulation (CE) no. 765/2008 dated July 9, 2008 annex II conformity symbol.
2 Equipment group. Group II: electrical equipment for use in potentially explosive atmospheres due to gas, other
than mines.
Equipment category subject to certification for potentially explosive atmospheres certification due to Gas, Mist (G).
3
The equipment can be installed in zone 1.
The electrical protection mode used for equipment corresponding to the protection by explosion proof case - suited for
4
gases in groups IIB and IIA.
5 The mechanical protection mode for equipment is through emersion h – suited for gases in groups IIB and IIA.
6 Equipment temperature class (maximum surface temperature 135°C).
7 Equipment with high protection level (EPL Gb), suitable for installation in Zone 1.
8 Working temperature.
RATING PLATE IDENTIFICATION (GENERAL PART)
0477
Monselice-PD ITALY
EPT 17 ATEX 2701 X
1
kW
P
2
3
Hz
5
6
9
Q L/min
12
1 Electropump type*
2 Serial number
3 Motor power
4 Voltage rating
5 Frequency
6 Liquid temperature
7 Nominal absorption
8 Capacitor
9 Manufacture year
RATING PLATE IDENTIFICATION (ATEX STRING)
Ex db IIB T4 Gb
II 2G
2
3
Ex h IIB T4 Gb
0°≤ Ta ≤ 40°
8
II 2G
16
S/N°
V
4
A
°C
7
CLASS F 68
10
Hm
13
14
Insulation class and motor
10
protection
11 R.P.M.
12 Capacity
13 Head
Maximum depth of
14
immersion
15 Pump weight
16 ATEX string marking
17 ATEX string marking
4
5
- 23
Ex db IIB T4 Gb
Ex h IIB T4 Gb
17
0°≤ Ta ≤ 40°
2
µF
8
N/1'
11
Kg
15
20m
7
6