• With the thumb-lock connector lever in the open position (Fig.
9), place connector over the tire stem and fold the lever over
(A) until the connector locks securely on the tire stem (Fig.
10).
Thumb-lock
..... ,..
connector
;_',
t
\
/Jl/
F
..........
J
_'
Fig. 9
Thumb-lock
connector
(locked) _
Fig. 10
Ensure the compressor is plugged-in and switch to the "ON"
position.
Open the ball-valve at the base of the inflation hose to begin
inflating (Fig. 11). You may adjust air flow by turning the ball
valve between 0 - 90 degrees.
Ball-Valve
opened
_
i
......_
Fig. 11
Monitor inflation pressure using a tire pressure gauge until the
required pressure is achieved (be sure not to exceed the tire
manufactures
maximum tire pressure).
• Turn ball-valve to the "closed" position (Fig. 8) when inflation is
complete.
DRAINING
THE TANK
See figure 12.
To help prevent tank corrosion and keep liquid and vapor
condensate out of the air supply, drain the compressor tank at
the end of each day's use.
To drain the tank:
Holding the compressor by its handle, tilt it in the direction of
the drain valve so that the valve is set in a lower position.
Open the drain valve by rotating it ¼ turn counterclockwise
(fig. 12).
Keep the unit tilted until all liquid and vapor condensate has
been drained into a suitable container.
NOTE: Condensate is a polluting material; dispose of it in
compliance with local regulations.
Close the drain valve by rotating it ¼ turn clockwise (fig. 12).
If drain valve is clogged, unplug air
compressor, release tank pressure by pulling the safety valve
ring, and contact a qualified repair facility for service.
CHECKING
THE SAFETY
VALVE
See figure 13.
Do not attempt to tamper with safety valve.
Anything loosened from this device could fly up and hit you.
Failure to heed this warning could result in death or serious
personal injury.
The safety valve wilt automatically release air if the air receiver
pressure exceeds the preset maximum. The valve should be
checked before each day of use by pulling the ring by hand.
• Turn the air compressor on and allow the tank to fill. The compressor
will shut off when the pressure reaches the preset maximum.
• Turn the air compressor off.
Pull the ring on the safety valve (fig. 13) to release air for
twenty seconds.
Fig. 13