Dometic GROUP WAECO CoolFreeze CFX35 Instrucciones De Uso página 36

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
Operation
In "HIGH" mode, the battery monitor responds faster than at the
levels "LOW" and "MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restartvoltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
The battery monitor mode can be selected as follows:
➤ Switch on the cooler.
➤ Press the "SET" button (fig. 3 4, page 3) three times.
➤ Use the "UP +" (fig. 3 7, page 3) or "DOWN -" (fig. 3 6,
page 3) buttons to select the battery monitor mode.
✓ Digital display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
✓ The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the
current temperature.
I
NOTE
When the cooler is supplied by the starter battery, select the bat-
tery monitor mode "HIGH". If the cooler is connected to a supply
battery, the battery monitor mode "LOW" will suffice.
36
CFX35 – CFX65DZ
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
HIGH
11.8 V
12.6 V
24.6 V
26.2 V
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido