3. Specification
3.1 Overview and dimensions
Fig. 1: Overview and dimensions
1 Operating mode key, heating operation
2 Operating mode key DHW operation
3 Display
4 OK key (acknowledgement)
5 ESC key (cancel)
3.2 Specification
Tab. 1: Specification
Model
Feed
Capturing range
Tolerance room temperature capture
Range 15...25 °C
Range 0...15 °C or 25...50 °C
Connection
Enclosure IP rating to EN 60529
Protection class to EN 60730
* Accessory
136231-02 10.15
2
5
80
BUS power supply via system con-
Room device RGT B/RGTK B and RGTF B/RGTKF B
1
3
4
6
7
8
9
6 Rotary selector
7 Presence key
8 Cooling mode (only RGTK/RGTKF)
9 Information key
RGT/RGTK
troller
(FB connection)
0...50 °C
0.8 K
1K
3-core to FB
IP 20
Protection class III
Specification
42
RGTF/RGTKF
3 batteries Mignon AA
Wireless connection via FEK receiver
to system controller (terminal X60),
Frequency 868 MHz
GB
*
27