Setting The Dip Switches - Dometic MCA1215 Instrucciones De Montaje Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 95
Connecting the device
The pins for the ESB socket (starter battery connection) are assigned as follows:
Pin in
fig. 9, page 6
+
8.5

Setting the DIP switches

You can adjust the device using the DIP switch.
S1 is used to set the voltage at which the device switches over from the I phase (bulk)
to the U0 phase (absorption) (also see chapter "Battery charging function" on
page 17). S3 must be set to "OFF".
S2 is used to set the retention voltage. S3 must be set to "OFF".
When a battery sensor is connected, the output voltages is adapted to the
temperature for these two functions:
• MCA 12xx: –20 mV/°C
• MCA 24xx: –40 mV/°C
S3 activates the power mode when either S1 or S2, or both, are set to "Off". In power
mode, the short circuit, overvoltage and overheating protection are controlled by
the internal sensor.
When S1, S2 and S3 are set to "On", then the function control by external devices is
activated. Among others the type of battery and the charging voltage are set using
the external device in this mode.
S4 regulates the fan function. When S4 is set to "On", then the fan is switched to
sleep mode (noise-reduced mode). When S4 is set to "Off", then the fan is not
regulated.
24
Allocation
VCC
GND
MCA1215 – MCA2440
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Mca1225Mca1235Mca1250Mca1280Mca2415Mca2425 ... Mostrar todo

Tabla de contenido