MCA1215 – MCA2440
14
Technical data
General technical data
Battery types:
Heat dissipation:
Charge mode:
Maximum ambient temperature:
Storage temperature:
Air humidity:
Temperature coefficient:
Temperature compensation (MCA12xx)
Temperature compensation (MCA24xx):
Vibration:
Voltage insulation:
Insulation resistance:
Alarm signal:
Communication:
Sleep mode (noise-reduced mode):
Remote control (accessory):
Testing/certification:
EN
MCA12xx, MCA24xx
Lead-acid, gel, AGM, Li-Ion
Fan
5-level
–20 °C – +50 °C
–40 °C – +85 °C
20 – 90 %
± 0.03 %/°C (0 – 50 °C)
–20 mV/°C (battery sensor)
–40 mV/°C (battery sensor)
10 – 500 Hz
2 g for 10 min/cycle within 60 minutes for X, Y and
Z axis
I/P – O/P: 4 kVw
I/P – FG: 1.7 kVw
O/P – FG: 0.7 kVw
I/P – O/P: 100 MΩ/500 Vg
via relay contact
via LIN-BUS
via remote control (accessory) or DIP switch
On/off switch, three-colour LED, sleep mode
option
Technical data
31