Cooper Hand Tools Weller WD 1 Manual De Uso página 43

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
2 sec.
III (EXIT)
4.1 Special functions menu 1
If the UP and DOWN buttons are pressed simultaneously,
after approx. 2 s the menu selection for the special functions
is activated and - I - appears in the display, release buttons.
Menu selection
The following settings are possible:
Offset, setback, standby temperature, OFF time, lock functi-
on, window, temperature version.
Buttons I and II are used for menu selection.
Button III is used to leave the menu again.
Resetting the calibration to factory settings
Press and hold the III key. Then press the UP and DOWN keys
at the same time. "FSE" appears in the display. You can now
reset the soldering station to its factory calibration.
4 sec.
-1-
-2-
Menu 1
Exit
I
STANDBY
SETBACK
OFF
OFFSTET
WINDOW
°C / °F
4.1.1 Standby temperature
When the set setback time has elapsed, the specified tempe-
rature is decreased automatically to the standby value. The
actual temperature is displayed (flashing) and "STANDBY"
appears in the display (100 - 300°C/200 - 600°F).
Adjust the standby temperature with the UP or DOWN button.
Switch to previous menu item with I.
Switch to next menu item with II.
4.1.2 Setback time
If the soldering tool is not being used, the temperature is
decreased automatically to standby temperature (see 4.1.1)
after the specified setback time has elapsed. The setback
time, after which the soldering unit switches to standby
mode, can be set from 0 – 99 minutes. With the "ON" setting,
the Setback function with swithing holder (optional) is active
(see Page 166).
With a setting of "0 min", the setback function is switched
off. The setback status is indicated by a flashing actual value
display and "STANDBY" appears in the display. The setback
English
II
III
EXIT
36

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Weller wd 1 mWeller wd 1000Weller wd 1000 m

Tabla de contenido