Place the flange (no. 2) through the inside of the pool, fasten it to the recess (no. 11) with 8 screws (Fig 5). Make sure that
the word "TOP" is located on the upper part.
Cut the Liner which is inside the flange, so that the recess is free and proceed to assemble the projector.
4. ASSEMBLY
After the housing has been installed and the clamp inserted with the appropriate screws, then assemble the floodlamp.
Insert the cable in the cable duct (no. 13). Then, tighten the nut on the cable duct (no. 12). Take the precaution of leaving
1.5 m of cable wound on the body of the floodlamp (no. 7) in order to be able to remove the floodlamp to the edge of the pool
in the event that handling is required (Fig. 7).
Insert the entire floodlamp assembly in the housing and secure it in the bayonet socket by turning to the right (Fig. 8).
To completely ensure that the floodlamp is firmly secured in the housing, install the lock screw (no. 20) which is supplied
with the floodlamp kit (Fig. 9).
5. ELECTRICAL CONNECTION
You should make sure that the voltage received by the lamp is never more than 12V. The transformer must be able to supply
45VA for each led spotlight connected. For example, if you want to control 6 spotlights, you must connect them in parallel to
a transformer of at least 270VA.
The projector should only be operated underwater and anchored to the vertical walls of the pool. The spotlight is supplied with
heat protection, which in the event of excess temperature reduces the lighting level to avoid overheating
6. MAINTENANCE:
This projector does not require any type of maintenance. If the projector is not working properly, please contact our customer
attention department.
The inside of the projector should not be handled under any circumstances, as this would lead to losing the guarantee.
Attention: Before any handling ensure that there is NO voltage supplied to the floodlamp.
7. SAFETY WARNINGS:
People in charge of assembly should be suitably qualified for this type of work.
Avoid making contact with the electric voltage.
Comply with the current standards regarding accident prevention.
In this regard, the IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS SPECIAL WIRING SWIMMING
POOLS
All maintenance operations should be performed with the projector disconnected from the Mains.
Do not handle with wet feet.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components
which have been inserted or handled at locations other than its own premises.