11 Cleaning and maintaining the
studio flash unit

11.1 Checking cables and connectors

Check the studio flash unit's connecting
cables and connectors for damage each time
before you put it into use.
DANGER OF FIRE AND ELECTRIC SHOCK!
Damaged connecting cables and connectors
must be repaired or replaced by an
electrician.

11.2 Cleaning the studio flash unit

Observe the following safety instructions
before and during cleaning because of a
DANGER OF ELECTRIC SHOCK AND
BURNS:
- First, discharge the capacitor of the stu-
dio flash unit; to do so:
- move the power switch
flash unit to I (ON).
- press the TEST button
the capacitor by triggering the flash;
then immediately move the power
switch
of the studio flash unit to O
(OFF).
The power switch must be pressed wit-
hin half a second; otherwise, the capa-
citor undergoes recharging.
- Remove the power plug from the outlet.
- Let the studio flash unit cool for 30
minutes.
+
of the studio
to discharge
S
5. 7
E
R
V
O
- Avoid skin contact with the flash tube
or bulb of the modelling lamp.
- Never use water or damp cleaning
agents for cleaning.
Housing and reflector:
Remove dirt with a microfibre cloth only.
Flash tube and the bulb of the model-
ling lamp:
Only remove dust with a dust brush or a
dry, soft cloth.

11.3 Charging the flash capacitor

The output of the studio flash unit is
reduced if the capacity of the flash capacitor
decreases.
This happens if the studio flash unit has only
been used with low flash output or has not
been used at all for an extended period of
time.
To achieve the optimum output of the studio
flash unit once again, you must fully charge
the flash capacitor for at least 30 minutes:
• Press power switch
of the studio flash
unit so that it is in position I (ON).
• Press the PLUS
button as often as it
takes for the value 6.0 to appear in the
DIGITAL DISPLAY
.
k