ENGLISH
• TRC/MITTO series radio control programming.
• Function logic programming.
• Memory cancellation.
• Parameter reading.
For the programming procedure, refer to the appropriate UNIPRO
instruction manual. Connect the UNIPRO programmer to the TRC/MITTO
transmitter use UNITRC/UNIMITTO and UNIFLAT accessories supplied.
Connect the UNIPRO programmer to the QSC control unit by means of the
UNIDA and UNIFLAT accessories supplied. N.B.: The QSC control unit
cannot supply the UNIPRO programmer.
15) MANUAL RELEASE
The manual or emergency release is to be activated when a gate must be
opened by hand, and in all cases where the automation system fails to
operate or operates incorrectly. To carry out the emergency manoeuvre,
proceed as follows:
Insert the standard key into its appropriate seat (fig. 18) and rotate it
anticlockwise (90°), then rotate the release knob clockwise along its entire
stroke. This way the pinion is made to idle, and therefore allows the gate
to be opened by hand.
Warning: Do not push the gate leaf hard, but rather help it along its
entire stroke.
To reset motor-driven control, rotate the knob anticlockwise along its entire
stroke, and then rotate the standard key clockwise until it is held tight. Keep
the key in a safe place which is known to all the people concerned.
In the case where the release knob is supplied with a personalised key (fig.
18), proceed as follows:
Insert the personalised key into the lock, rotate the key anticlockwise by
90°.
Hold the release knob and rotate it clockwise (fig. 18) until it stops. This
way the pinion is made to idle, and therefore allows the gate to be opened
by hand.
Push the gate leaf by hand, helping it along its entire stroke.
The key cannot be taken out of the lock until the knob is brought back to
its initial position (motor-driven activation).
To reset motor-driven control, rotate the knob anticlockwise along its entire
stroke, move the key back to its locking position; then take the key out and
keep it in a safe place which is known to all the people concerned.
16) INSTALLATION CHECK
Before the automation device finally becomes operational, scrupulously
check the following conditions:
• Check that all the safety devices (limit microswitches, photocells, electric
edges etc) operate correctly.
• Check that the rack and pinion are correctly meshed (minimum play 2mm).
• Check that the pushing force of the gate is within the limits provided for by
the current standards.
• Check that the opening and closing end-of-stroke runners are correctly
positioned and tightly secured.
• Check the starting and stopping operations using the manual control.
• Check the starting and stopping operations using the remote radio control.
• Check the normal or customised operation logic.
17) AUTOMATION DEVICE USE
Since the automation device can be controlled both remotely and in sight,
by means of a radio control device or a button, all the safety devices must
be frequently checked in order to ensure their perfect efficiency.
WARNING! In the event of any safety device malfunction, request imme-
diate assistance from qualified personnel.Children must be kept at a safe
distance from the automation operation area.
The installer undertakes to instruct the user about correct automation
operation, also pointing out the actions to be taken in case of
emergency.
18) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed
automatically. There are different types of controls (manual, radio control,
magnetic card access etc.) depending on the installation requirements and
characteristics. For the various control systems, see the relevant instruc-
tions.
19) MAINTENANCE
WARNING! Before proceeding to any maintenance, disconnect the
mains power supply and, if the battery is fitted, one of its poles.
These are the check and maintenance operations to be carried out:
• Check the condition of lubrication of the metal racks once a year.
• Keep the sliding track always clean and free from debris.
• Occasionally clean the photocell optical elements.
• Have a qualified technician (installer) check the correct torque limit setting.
When any operational malfunction if found, and not resolved, discon-
nect the mains power supply and request the assistance of a qualified
technician (installer). When the automation controller is out of service,
you can activate the manual release device (see paragraph on "Emer-
18 -
DEIMOS BT Ver. 04
INSTALLATION MANUAL
gency manoeuvre") in order to set the pinion idling and therefore allow the
gate to be opened and closed by hand.
20) MALFUNCTIONS AND REMEDIES
20.1) Faulty actuator operation
• Use an appropriate instrument to check that the actuator ends are
supplied with voltage after the opening or closing command.
• If the leaf movement is opposite to that required, reverse the motor drive
connections in the control unit.
• Leaf stop: when the working time is insufficient, the leaf may not
complete its stroke. Slightly increase the working time in the control unit.
20.2) Faulty operation of electrical accessories
In case of fault, all the control and safety devices can cause the automation
controller to malfunction or lock. If the control unit is provided with self-
diagnosing facility, identify the fault. If a fault is found, it is advisable to
disconnect and, if necessary, bridge, all the automation control devices one
by one, until the one causing the fault is identified. Replace or repair it, then
reset all the devices which were previously disconnected or bridged. For all
the devices installed, make reference to the respective instruction manual.
21) SCRAPPING
Materials must be disposed of in conformity with the current regula-
tions. In case of scrapping, the automation devices do not entail any
particular risks or danger. In case of materials to be recycled, these should
be sorted out by type (electrical components, batteries, copper, aluminium,
plastic etc.).
22) DISMANTLING
When the automation system is disassembled to be reassembled on
another site, proceed as follows:
• Disconnect the power supply and the entire external electrical installation.
• In the case where some of the components cannot be removed or are
damaged, they must be replaced.
WARNING!
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
standards relating to safety, installation and good technical practice,
as well as the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any altera-
tions deemed appropriate for the technical, manufacturing and com-
mercial improvement of the product, while leaving the essential
product features unchanged, at any time and without undertaking to
update the present publication.
http://www.bakonline.net/

Publicidad

Tabla de contenido
loading

Tabla de contenido