Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Problem
The control panel does not work
and no LED indicator comes on
The operator does not work when
the key commands are enabled
PWR lit up, PT1 and PT2 off
The operator does not work when
the key commands are enabled
PWR lit up, PT1 and PT2 lit up,
ST1 and ST2 off when operating the
A.T and C.T. key commands
The leaf does not reach the
stopper
PT1 and PT2 lit up
The leaf does not reach the stopper
PT1 or PT2
off
The shutter gate opens but does
not close
PT2 off
The shutter gate opens but does
not close
PT2 lit up
The shutter gate closes but does
not open
PT1 off
The shutter gate closes but does
not open
PT1 lit up
The control panel works correctly but
does not obey the transmitter
4

SCRAP

The control panel, up until the end of its useful life,
must be dismounted at its location by an installer
who is as well qualified as the person who
completed the assembly, observing the same
precautions and safety measures. In this manner
possible accidents and damage to adjacent facilities
will be avoided.
Cause
General switch SW1 in "OFF"
Power supply voltage absent
Main fuse F1 blown
Electronic fuse F2 blown
Transformer or panel failed
Safety devices (photocells or strips)
enabled or defective
The key commands signal does not
reach the control panel
Hard points in the shutter gate run
Operation time incorrectly set
Limit switches incorrectly adjusted
Opening safety device (photocell or
strip) enabled
Closing safety device (photocell or
strip) enabled or defective
Closing limit switch continuously
enabled or deteriorated
Opening safety device (photocell or
strip) enabled or defective
Opening limit switch continuously
enabled or deteriorated
T r a n s m i t t e r
c o d e
i n c o r r e c t l y
programmed
Transmitter batteries flat
}
The control panel must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying the different materials in line with their nature.
NEVER deposit it in domestic rubbish or in landfills which
are
environmental contamination.
MAINTENANCE AND DIAGNOSIS OF FAILURES
Solution
Place SW1 in "ON"
Restore the power supply voltage
Replace F1 using another fuse of the same
value and investigate the cause of failure of
F1
Replace F2 using another fuse of the same
value and investigate the cause of failure of
F2
Call the technical service
C h e c k t h e s a f e t y d e v i c e s a n d t h e
connections
Check the key command devices and the
connections
Move by hand and remove the hard points
Set the T.E. power meter
Correctly set the limit switches
Remove any possible obstacles
C h e c k t h e s a f e t y d e v i c e s a n d t h e
connections
Check FCC and its connections
C h e c k t h e s a f e t y d e v i c e s a n d t h e
connections
Check FCA and its connections
See "Radio code programming" on
page 32
Replace the batteries, checking the
instructions for the transmitter
not
suitably
controlled,
as
this
will
cause
35
CLEVER02 Control panel

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido