1) GENERAL INFORMATION
GSM receiver designed to command relay contacts through recognition of
authorized telephone numbers. The GSM receiver can store up to 99 telephone
numbers. These numbers activate the output OUT 1 through a call. You can
store up to 8 recipients who, if authorized, receive messages from the receiver.
Furthermore, the two outputs can be controlled either on a timed basis or through
SMS text messages.
2) TECHNICAL SPECIFICATIONS
Power supply
Operating temperature range
OUT 1
OUT 2
IP rating
Band
Max. telephone numbers stored in memory 99
SIM card type
Antenna
Typical standby power demand
Supply voltage
12
12~
24
24~
NOTE: the following convention is used herein:
- Activation OUT 1 --> 5-6 terminals output NC
- Activation OUT 2 --> OUT 2 --> 8-4 terminals output NC
The default password is 123456. The code to be sent MUST NOT contain spaces and must be written in UPPER CASE. Every time a text message is sent, the controller
answers the sender with a reply text.
Checking the GSM signal:
Excellent signal
=31
Good signal
=16
Sufficient signal
=12
Poor signal
<12
Should the signal be lower than 12, find a new location for the board or switch to a telephone provider with a better signal in the area in question.
Code to be sent
#PWDpassword#CSQ?
N.B. If you do not receive a reply text, it probably means you are not in an area covered by the telephone provider's GSM signal.
Adding a new telephone number to the memory (maximum 99 numbers).
The telephone number must contain no more than 10 digits (no country code).
Note: for some telephone providers, the telephone number must be recorded in the GSM Receiver with the last 9 or 8 digits.
Code to be sent
#PWDpassword#WHLposition in memory=telephone
number
In the example, the telephone number 0123456789 is added in position 1; telephone number 9876543210 in position 2; and telephone number xxxxxxxxxx in
position 99.
Dial the telephone number of the SIM card inserted in the board from a telephone with a number entered in the memory. The call will automatically be rejected
or the number called will turn out to be busy, so there is no charge. The board activates output OUT1.
How to change the password to manage the various programming functions. The password must be made up of 6 digits.
The default password is 123456. All examples in this manual will have 123456 as the password.
Code to be sent
#PWDpassword#CAPnew password#CAPnew password
In the example, the password is changed to 321654. #PWD321654#......
Set the OUT1 output activation time in the range 1 to 99 sec. (default setting 1 sec.) when the controller receives a call from a number stored in the memory.
Code to be sent
#PWDpassword#GOTout1 output activation time in sections
In the example, output OUT1 is activated for 5 sec. whenever the controller receives a call from a number stored in the memory.
Checking a telephone number stored in a given position in the memory
Checking a stored mobile number based on its position in the memory.
Code to be sent
#PWDpassword#WHLposition in memory?
In the example, position 02 in the memory is queried.
INSTALLATION MANUAL
12V/ 24V ~
+ -10%
-5 / +50°C
NO contact (Max. 120V~/24
1A)
NO/NC contact (Max. 24V
1A)
IP55
Tri-Band GSM/GPRS 900/1800/1900 MHZ
GSM
3V / 1.8V
3.5dB – 5dB
Consumption (mA)
<120mA
<200mA
<60mA
<120mA
GSM signal quality
Sample text to be sent
#PWD123456#CSQ?
Adding a new telephone number to the memory
Sample text to be sent
#PWD123456#WHL01=0123456789
#PWD123456#WHL02=9876543210
...................................................
...................................................
#PWD123456#WHL99=xxxxxxxxxx
How to activate output OUT1
Changing the password
Sample text to be sent
#PWD123456#CAP321654#CAP321654
OUT1 output activation time
Sample text to be sent
#PWD123456#GOT05
Sample text to be sent
#PWD123456#WHL02?
3) TUBE ARRANGEMENT FIG. A
4) DIMENSIONS FIG. B
5) PUNCHING OUT KNOCKOUT HOLES FIG. C
6) TERMINAL STRIP WIRING FIG. D
Terminal
Description
1-2
Power supply 12V / 24 ~
8-3
OUT 2 NC contact (max. 24V
8-4
OUT 2 NO contact (max. 24V
5-6
OUT 1 NO contact (max. 120V ~ / 24V
7
Input <IN>
7) INSERTING THE SIM CARD FIG. E
Use SIM card without PIN/PUK number.
Note: you need to remove the SIM card PIN request before inserting it in the board,
otherwise the device will not work. To do this, insert the SIM card in a telephone
and disable the PIN request (there's usually a security menu that allows you to
do this). If you don't do this, after turning the phone on 3 times, you will be asked
for the PUK number again to reset the SIM card.
8) ADDING A NEW NUMBER TO SIM CARD FIG. F
9) ACTIVATING THE OUT 1 CONTACT OUTPUT FIG. G
10) OUT 2 CONFIGURATION FIG. H
Ref. 1 - Free contact (max. 24V
Ref. 2 - Powered contact (based on 12V/24V
11) USE OF <IN> INPUT FIG. I
Connect 12V
to produce increased counter count.
12) PERSONAL LIST FIG. J
CSQ<23>
WHL01:
0123456789
WHL02:
9876543210
....................................
WHL99:
xxxxxxxxxx
CAP: 321654
GOT: 05
WHL02: 9876543210
1A)
1A)
1A)
1A)
supply voltage)
Sample text received
Sample text received
Sample text received
Sample text received
Sample text received
GSM RIC 24 V -
11