Set the message that will be sent to authorized recipients in the memory when <IN> contact is closed.
The message must be no more than 100 characters long. Only use letters and numbers abc/ABC/123; do not use special characters (&, %,*, etc.).
Code to be sent
#PWDpassword#STR=message text
The message that will be sent is: GATE CLOSED.
Set the message that will be sent to authorized recipients in the memory when <IN> contact is opened.
The message must be no more than 100 characters long. Only use letters and numbers abc/ABC/123; do not use special characters (&, %,*, etc.).
Code to be sent
#PWDpassword#STO=message text
The message that will be sent is: GATE OPEN.
Set the number of times the <IN> contact is closed after which, or after multiples of which, a warning message is sent to authorized recipients.
Min. 1
Max. 65535
Default setting 500
The command to be sent is made up of 5 digits:
Code to be sent
#PWDpassword#COA=number of times contact must be
closed before message is sent
In the example, message sending has been set to the 5th, 10th, 15th time etc. the <IN> contact is closed.
Function 1: (default setting)
-
The board counts the number of times input <IN> changes state.
-
The board sends the warning message when the counter reaches the value set by command #COA.
Function 2:
-
The board counts the number of times input <IN> changes state.
-
Output OUT2 is activated when input <IN> first changes state.
-
The board sends the warning message when the counter reaches the value set by command #COA.
Function 3:
-
The board counts the number of times input <IN> changes state.
-
Output OUT2 is activated when input <IN> first changes state.
-
The board sends the
#STR warning message every time input <IN> is closed.
-
The board sends the warning message when the counter reaches the value set by command #COA.
Function 4:
-
The board counts the number of times input <IN> changes state.
-
Output OUT 2 is activated for 1 sec. every time input <IN> is closed.
-
The board sends the warning message when the counter reaches the value set by command #COA.
Function 5:
-
The board sends the
#STR warning message every time input <IN> is closed.
Function 6:
-
The board sends the
#STR warning message every time input <IN> is closed.
-
The board sends the
#STO warning message every time input <IN> is opened.
Code to be sent
#PWDpassword#CTC=function number
Function 4 is enabled in the example.
Checks the total number of times input <IN> has changed state. The number increases every time the contact is closed.
Code to be sent
#PWDpassword#COU?
In the example, the total number of times the input has changed state is 143.
Checks the partial number of times input <IN> has changed state. The number increases every time the contact is closed and is reset when the value reaches the value set in #COA.
Code to be sent
#PWDpassword#COT?
In the example, the partial number of times the input has changed state is 4.
Both the total and partial counters are reset to 0.
Code to be sent
#PWDpassword#CLA
INSTALLATION MANUAL
Warning message when <IN> contact is closed
Sample text to be sent
#PWD123456#STR=Gate closed
Warning message when <IN> contact is opened
Sample text to be sent
#PWD123456#STO=Gate open
Setting input <IN> partial counter
Sample text to be sent
#PWD123456#COA=00005
Setting advanced functions
Sample text to be sent
#PWD123456#CTC=4
Checking the total number of times input <IN> has changed state
Sample text to be sent
#PWD123456#COU?
Checking the partial number of times input <IN> has changed state
Sample text to be sent
#PWD123456#COT?
Sample text to be sent
#PWD123456#CLA
String:
Gate closed
STRALM1:
Gate open
COA=00005
Every time the contact is closed.
Every time the contact is closed.
See #RLOP function for instructions on de-energizing the relay.
Every time the contact is closed.
See #RLOP function for instructions on de-energizing the relay.
Every time the contact is closed.
CTC=<4>
INC:
00143
COT:
00004

Counter reset

RECO-OK
Sample text received
Sample text received
Sample text received
Sample text received
Sample text received
Sample text received
Sample text received