Outputs OUT1 and/or OUT2 are activated for a settable time. The outputs are independent.
Min. 1 sec., Max. 65535 sec.
Out1=1, Out2=2
The command to be sent to indicate the number of seconds is made up of 5 digits:
Code to be sent
#PWDpassword#RLYoutput to be activated=length of time
output stays active in seconds.
In the example, output 2 stays active for 1 and a half hours.
Displays the seconds remaining, since relays were activated.
Code to be sent
#PWDpassword#RLY?
In the example, output 2 stays active for another 1 hour 20 minutes.
The outputs are activated or deactivated. The outputs are independent.
Out1=1, Out2=2
1=ON; 0=OFF
Code to be sent
#PWDpassword#RLOPoutput to be activated=command
In the example, output OUT2 is activated.
Function 0: (default setting)
-
Normally deactivated outputs. Special functions are disabled. Normal mode.
Function 1:
-
Normally activated outputs. Every time a call is made from telephone numbers stored in the memory, output OUT1 is deactivated for 10 sec. and,
after 30 seconds, output OUT2 is deactivated for 5 sec.
Function 2:
-
Normally activated outputs. Programming deactivation of outputs based on time of day. Calls from telephone numbers stored in the memory are
disregarded.
Code to be sent
#PWDpassword#FTRY=function number
Function 2 is enabled in the example
Programming deactivation of outputs OUT1 and OUT2 based on time of day
Determines at what time individual outputs are deactivated and for how long.
8 times can be programmed.
SS,MM,HH,TTT,G,R; BE CAREFUL TO GET THE COMMAS AND SEMI-COLON IN THE RIGHT PLACE.
Code to be sent
#PWDpassword#SMW=seconds,minutes,hour,output
deactivation time in seconds,number of times programmed,relay
programmed;
In the example, output OUT2 is deactivated at 18:48:00 for 15 sec.
Set time in 24-hour format
SS,MM,HH,TTT,G,R; BE CAREFUL TO GET THE COMMAS AND SEMI-COLON IN THE RIGHT PLACE.
Code to be sent
#PWDpassword#TSET=seconds,minutes,hour;
In the example, the clock is set to 08:30:00.
--------------------------------------------------------------------------------------------------------------------------------------------------
Restores the controller's factory settings.
N.B. the telephone numbers stored in the memory are not deleted.
Code to be sent
*REST#password
Code to be sent
#PWDpassword#EDI?
14 -
GSM RIC 24 V
INSTALLATION MANUAL
MANUAL MODE:
Activation of outputs OUT1 and OUT2 for a given time
Sample text to be sent
#PWD123456#RLY2=05400
Checking output state
Sample text to be sent
#PWD123456#RLY?
Activating/deactivating outputs OUT1 and OUT2
Sample text to be sent
#PWD123456#RLOP2=1
TIMED MODE
Special output functions
Sample text to be sent
#PWD123456#FTRY=2
...........
#PWD123456#FTRY=0
Sample text to be sent
#PWD123456#SMW=00,48,18,015,1,2;
Internal clock set
Sample text to be sent
#PWD123456#TSET=00,30,08;
Board reset
Sample text to be sent
*REST#123456
Checking software and hardware version
Sample text to be sent
#PWD123456#EDI?
Sample text received (to message recipients only)
RLY2=05400
...........
Once the time has expired (0000), the contact is deactivated
and the gsm sends the following message:
RELY2-OFF
Sample text received
RELAY1=00000S
RELAY2=04800S
Sample text received (to message recipients only)
RLOP2-ON
Sample text received
FTRY:2
...........
FTRY:OFF
(and to message recipients only)
RELY1-OFF
RELY2-OFF
Sample text received
SMW:00,48,18,015,1,2
Sample text received
TIME:00,30,08
Sample text received
REST-OK
Sample text received
Software release time:<WT-009_LIA>2009/8/08/10:45HW:1
.0SW:1.0MW:2.3>