USER MANUAL
ANTIX
BY LRP
Dear customer,
thank you for your trust in this ANTIX by LRP product. By purchasing a ANTIX by LRP
HV-LIPO battery, you have chosen a high-performance battery for your RC model. Plea-
se read the following instructions to ensure, that your ANTIX by LRP HV-LIPO battery
always works up to your full satisfaction.
LiPo-batteries need special treatment and care. Please read the following instructions
carefully before you start using your ANTIX by LRP HV-LIPO battery. This user guide
contains important notes for the installation, the safety, the use and the maintenance of
this product. Thus protecting yourself and avoid damages of the product.
Proceed according to the user guide in order to understand your ANTIX by LRP HV-LI-
PO battery better. Please take your time as you will have much more joy with your
product if you know it exactly.
This user manual shall be kept in a safe place. If another customer is using this pro-
duct, this manual has to be handed out together with it.
1. HV-LIPO
The all-new HV line batteries from ANTIX by LRP are truly something new and innova-
tive. In comparison to normal LiPo batteries, these new HV batteries feature a nominal
voltage of 3.8V (instead of 3.7V) per cell and therefore can be charged up to 4.35V! This
results in more power and more runtime. You can feel the extra power as your model
will accelerate faster and run for a longer time. The HV batteries are compatible with all
standard LiPo chargers and will perform like a normal LiPo battery.
IMPORTANT: The HV batteries are 100% compatible for charging to 4.20V per cell. No-
netheless they have significantly more power than our 2016 batteries at 4.20V charge
and as a positive side effect, they will have a highly improved lifetime.
2. CONNECTIONS
Most of the ANTIX by LRP batteries are already equipped with a ready-to-use power
connector. Those power connectors have to be used for charging the LiPo and for any
application inside the model. All ANTIX by LRP batteries feature a XH-balancer-con-
nector. This connector is used for equalizing the voltage of the individual cells inside a
battery pack. Never cut or remove this connector under any circumstances. Chargers
use this balancing port to perfectly condition and equalize the individual cells inside
the pack. For perfect charging and conditioning of the batteries, we recommend the
Quadra Competition V1 charger from LRP electronic (LRP No. 41420).
ATTENTION: The Balancing-port shall not be used for the standard use in the model/
device. Only use the power connectors to power your model/device.
Balancing-port 3-pole (2S - 7.6V packs)
Black (Battery-Negative)
Black (cell connection 1)
Red (Battery-Positive)
Balancing-port 4-pole (3S - 11.4V packs)
Black (Battery-Negative)
Black (cell connection 1)
Black (cell connection 2)
Red (Battery-Positive)
Balancing-port 5-pole (4S – 15.2 packs)
Black (Battery-Negative)
Black (cell connection 1)
Black (cell connection 2)
Black (cell connection 3)
Red (Battery-Positive)
3. CHARGING
Due to new and special manufacturing technologies, all ANTIX by LRP HV-LIPO batte-
ries can be charged with a maximum current of 3C*. For charging, only use chargers,
which are specially designed and developed for LiPo-batteries. These chargers charge
the battery with the max. current till the battery reaches the max. charging voltage.
The charger then reduces the charging current until the battery is fully charged. This
charging method is called CC/CV (Constant Current/Constant Voltage).
For charging the ANTIX by LRP batteries, we recommend the Quadra Competition V1
charger from LRP electronic (LRP No. 41420).
ATTENTION: Under no circumstances use NiMH/NiCd-chargers or chargers, that are
set to NiMH/NiCd mode, for charging LiPo-batteries! These chargers do not reduce the
charging current and therefore ultimately lead to overcharging the battery! Only use
chargers that have an automatic end of charge cut-off and are specially designed for
radio controlled model batteries. Do not use timer chargers.
ANTIX by LRP HV-LIPO batteries batteries do not heat up during charging. It is normal,
AA00672 © LRP electronic GmbH 2017
HV-LIPO PACKS
Cell 1-
Cell 1+ (Cell 2-)
Cell 2+
Cell 1-
Cell 1+ (Cell 2-)
Cell 2+ (Cell 3-)
Cell 3+
Cell 1-
Cell 1+ (Cell 2-)
Cell 2+ (Cell 3-)
Cell 3+ (Cell 4-)
Cell 4+
Battery disposal notes: Batteries and accumulators used in this product are to be disposed of separately from your household waste. Batteries and accumu-
lators must not be disposed of as unsorted municipal waste. Users of batteries and accumulators must use the available collection framework for the return,
recycling and treatment of batteries and accumulators. Customer participation in the collection and recycling of batteries and accumulators is important to
minimise any potential effects of batteries and accumulators on the environment and human health due to substances used in batteries and accumulators.
that the battery still has ambient temperature when it is fully charged. If the battery
heats up during charging or warps, immediately stop charging it. A Balancer which mo-
nitors the voltage of each single cell is mandatory during the charge of LiPo batteries.
ATTENTION: Never charge your LiPo battery without a balancer directly connected
to the balancing port of your battery, unless your charger is already equipped with a
balancer. Always charge your battery outside of your model!
The maximum charging voltage for each single LiPo-cell is 4.35V. If the battery reaches
this voltage, the charge current has to be lowered. This is automatically done by the
charger. If the charge current reaches 0.05 - 0.1C*, the battery is fully charged. Some
ANTIX by LRP HV-LIPO batteries batteries consist of multiple LiPo-cells. You can see
the max. charging voltage in the table below. We advise the following settings for
charging our ANTIX by LRP HV-LIPO batteries batteries:
Cell configuration
ANTIX by LRP LiPo - 2S - 7.6V
ANTIX by LRP LiPo - 3S - 11.4V
ANTIX by LRP LiPo - 4S - 15.2V
ANTIX by LRP LiPo - 5S – 19.0V
ANTIX by LRP LiPo - 6S – 22.8V
ATTENTION: ONLY CHARGE OUR LRP HV LINE LIPO BATTERIES UP TO A CHARGING
VOLTAGE OF 4.35V PER CELL. ONLY THESE TYPES ARE SUITABLE FOR THIS. UNDER
NO CIRCUMSTANCES CHARGE NORMAL LIPO BATTERIES UP TO THIS CHARGING
VOLTAGE! FIRE HAZARD!
PLEASE NOTE: You can use your ANTIX by LRP HV-LIPO PACKS battery several times
a day. However be sure, that the battery has completely cooled down to ambient tem-
perature, before re-charging it again.
ANTIX by LRP HV-LIPO batteries batteries do not have a memory effect and only a very
low self-discharge rate. Therefore you can also charge batteries with a partial charge
in them, without the need of discharging the pack before. Partially charged packs can
be stored over a long period of time, without getting damaged. Please also see the
„Storage" section for further reference.
* C=Nominal capacity of the battery. E.g. with a nominal capacity of 7000 mAh (7.0Ah),
the battery can be charged with a max. current of 21.0A.
4. DISCHARGING
When discharging your LiPo battery with high current, please make sure the LiPo packs
is cooled properly.
ATTENTION: The max. temperature of the LiPo-battery during discharge must never
exceed 60°C (140°F). You have to take care, that the batteries do not get deep dischar-
ged. As soon as the battery voltage falls below 3.3V per single cell, the battery pack
gets damaged irrevocably. 2S = 6.6V; 3S = 9.9V; 4S = 13.2V; 5S = 16.5V; 6S = 19.8V.
The battery voltage should never fall below these discharge cut-off voltages. If your
speed control does not have a special undervoltage protection for LiPo-batteries, you
have to stop your model early enough in order not to deep discharge the battery pack.
Therefore stop immediately as soon as you feel a rapid loss in power.
NOTE: If the batteries do swell or get thick after discharging them, it is a sign of over-
load and/or deep-discharge. The battery pack gets damaged due to this and the max.
performance will drop. You should stop using a LiPo pack which is significantly bal-
looned and you should neither charge it nor use it inside your model. SWOLLEN BAT-
TERY PACKS ARE NOT A PRODUCT FAULT AND THEREFORE EXCLUDED FROM THE
LIMITED WARRANTY.
5. SPECIAL NOTES FOR HANDLING
• Make sure to set your eletronic speed control cut-off voltage to the correct LiPo
battery voltage, depending on the battery you are using. A wrong cut-off voltage can
lead to deep-discharging the battery, which damages it battery irrevocably.
• Avoid short-circuits! Short-circuiting the battery results in very high currents, which
damage the internal structure of a LiPo-battery. This leads to a loss of power and
capacity.
• Never charge LiPo batteries without a balancer. Charging without a balancer can
damage the battery. Please note, that your limited warranty will void if you charge
without balancer.
• Be sure, not to damage the outside of the LiPo-battery. The battery is only protected
by a heatshrink. The actual Lipo-cell is directly under this heatshrink. If the outer skin
of the cell gets damaged, the battery can no longer be used. Therefore take special
care, that no sharp objects like knifes, tools, carbon fibre edges or similar items can
damage the hardcase and/or the cells within it.
• When securing the LiPo-battery inside your model/device, you have to take care that
the LiPo-battery does not get damaged or warped in case of a crash. LiPo-batteries
are less mechanical resistant then NiMH-batteries in a metal can. Therfore pay spe-
LRP electronic GmbH
Hanfwiesenstraße 15
73614 Schorndorf
Deutschland
ENGLISH
max. charge
recommended
max. charging
current
charge current
voltage
3C*
1C*
8.70V
3C*
1C*
13.05V
3C*
1C*
17.40V
3C*
1C*
21.75V
3C*
1C*
26.10V

Publicidad