Problem
Engine is running, but no AC
output is available.
Engine
runs good at no-load
but
"bogs
down"
when
loads are
connected,
Cause
1,
One of the circuit breakers is
open,
2,
Poor connection or defective
cord set,
3,
Connected device is bad.
4.
1.
2.
3.
4.
1.
2.
Fault in generator,
Short circuit in a connected
load,
Generator is overloaded,
Engine speed is too slow.
Shorted generator circuit,
Fuel valve in the "Off' position.
Rocker Switch set to "Off'.
Correction
1,
Reset circuit breaker,
2,
Check and repair,
3,
Connect another device that is
in good condition.
4,
Contact Sears service facility.
1,
Disconnect shorted electrical
load.
2,
See "Don't Overload
Generator",
3,
Contact Sears service facility.
4,
Contact Sears service facility.
1,
Set fuel valve to the "On"
position.
2,
Set switch to "On",
3,
Dirty air cleaner.
4,
Out of gasoline.
5,
Stale gasoline,
3,
Clean or replace air,
4,
Fill fuel tank,
5,
Drain fuel tank; fill with fresh
fuel,
Engine will not start; or starts
and runs rough.
6,
7,
8.
9.
Spark plug wire not connected
to spark plug,
Bad spark plug,
Water in gasoline,
Overchoking,
10, Low oil level.
11, Excessively rich fuel mixture,
12, Intake valve stuck open or
closed,
13, Engine has lost compression,
Out of gasoline,
6,
Connect wire to spark plug,
7,
Replace spark plug,
8,
Drain fuel tank; fill with fresh
fuel,
9,
Open choke fully and crank
engine,
10, Fill crankcase to proper level.
11, Contact Sears service facility.
12. Contact Sears service facility.
13, Contact Sears service facility,
Engine shuts down during
Fill fuel tank.
operation.
1,
Load is too high,
Engine lacks power.
2,
Dirty air filter,
1,
Choke is opened too soon,
Engine "hunts"
or falters.
2,
Carburetor is running too rich or
too lean,
1,
2,
1,
2,
See "Don't Overload
Generator",
Replace air filter,
Move choke to halfway position
until engine runs smoothly.
Contact Sears service facility.
17