Dry the equipment.
•
Coil the tension belt. Refer to Fig. 16.
5.5.2
Store
NOTICE
Do not store the equipment before the tension belt is dry.
Damp material can be detrimental to the belt material and the metal.
•
Rub a light layer of WD-40 preservative oil on the steel parts.
•
Store the equipment in a dry and well-ventilated area.
6
Maintenance
6.1
General
Proper preventive maintenance of the equipment preserves the operational safety and extends the life
of the equipment.
CAUTION
When performing maintenance activities, always comply with the relevant safety regulations.
Wear the prescribed personal protection equipment.
6.2
Dangerous substances
CAUTION
Used or leaked fluids, and any other products consumed during the activities,
must be collected and disposed of in a environmentally responsible way.
6.3
Maintenance materials
/i
Application
Hinge pins
Steel parts
Contact the Holmatro dealer for information on spare parts.
6.4
Yearly maintenance
We recommend having the equipment inspected, checked, set and tested once a year by a Holmatro
Certified Technician who has the appropriate knowledge and the necessary tools.
The Holmatro dealer can organize the yearly maintenance for you on a contract basis. In this way you
are assured of correct and safe operation.
6.5
Long term storage
•
For long-term storage, apply preservative to the external steel parts.
•
Store the equipment in a dry, well-ventilated area.
V-STRUT
Type of maintenance material
Teflon lubricating oil
WD-40 preservative oil
Tectyl ML from Valvoline (long term preservation)
916.001.337_001
EN
Amount
As required
As required
As required
23