mabe MMI12CABWCAM8 Manual Del Propietário página 71

Ocultar thumbs Ver también para MMI12CABWCAM8:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

When the mounting plate is fixed side bar and lintel
1. Fix to side bar and lintel a mounting bar, which is separately sold,
and then fasten the plate to the fixed mounting bar.
2. Refer to the previous section, "When the mounting plate is first
fixed" for the position of wall hole.
2. Make a hole on the wall and fit the piping hole cover.
• Make a hole of 60 mm in diameter, slightly descending to out-
side the wall.
• Install piping hole cover and seal it off with putty after installa-
tion.
Wall hole
Ø60 mm
(Section of
Indoor
wall hole)
3. Routing the pipes
Rear piping
• Draw pipes and the drain hose, then fasten them with the ad-
hesive tape.
Left-Left-rear piping
• In case of left side piping, cutaway with a nipper the lid for left
piping.
• In case of left-rear piping, bend the pipes according to the pip-
ing direction to the mark of hole for left-rear piping which is
marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of
indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
unit, and pull it out on the front side, then connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely,
and make sure fixing with adhesive tape.
Lid for right piping
Lid for bottom piping
Fix with adhesive tape
G. Piping hole
Thickness of wall
Outdoor
Lid for left piping
71

Hide quick links:

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido