Guía de programación del convertidor de fre-
®
cuencia VLT
AQUA
16-61 Terminal 53 ajuste conex.
Option:
[0] *
Intensidad
[1]
Tensión
[2]
Pt 1000 [°C]
[3]
Pt 1000 [°F]
[4]
Ni 1000 [°C]
[5]
Ni 1000 [°F]
16-62 Entrada analógica 53
Range:
0.000 N/A*
[-20.000 - 20.000 N/A]
16-63 Terminal 54 ajuste conex.
Option:
[0] *
Intensidad
[1]
Tensión
[2]
Pt 1000 [°C]
[3]
Pt 1000 [°F]
[4]
Ni 1000 [°C]
[5]
Ni 1000 [°F]
16-64 Entrada analógica 54
Range:
0.000 N/A*
[-20.000 - 20.000 N/A]
16-65 Salida analógica 42 [mA]
Range:
0.000 N/A*
[0.000 - 30.000 N/A]
16-66 Salida digital [bin]
Range:
0 N/A*
[0 - 15 N/A]
Bit 0
Entrada digital, term. 33
Bit 1
Entrada digital, term. 32
Bit 2
Entrada digital, term. 29
Bit 3
Entrada digital, term. 27
Bit 4
Entrada digital, term. 19
Bit 5
Entrada digital, term. 18
Bit 6
Entrada digital, term. 37
Bit 7
Entrada digital GP E/S term. X30/2
Bit 8
Entrada digital GP E/S term. X30/3
Bit 9
Entrada digital GP E/S term. X30/4
Bit 10-63
Reservado para futuros terminales
Función:
Ver el ajuste del terminal de entrada 53. Intensidad = 0; Tensión = 1.
Función:
Ver el valor real en la entrada 53.
Función:
Ver el ajuste del terminal de entrada 54: Intensidad = 0; Tensión = 1.
Función:
Ver el valor real en la entrada 54.
Función:
Ver el valor real en mA en la salida 42. El valor mostrado refleja la selección realizada en
Terminal 42 salida
par. 6-50
.
Función:
Ver el valor binario de todas las salidas digitales.
®
MG.20.O3.05 - VLT
es una marca registrada de Danfoss
2 Descripción del parámetro
2
161