VGE Blue lagoon Serie Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
1. Determine where the device will be installed. Make sure to leave a free area (+/- 1 metre) in
EN
order to be able to remove the lamp (K) / quartz glass (M) for the purpose of replacement and/
or maintenance.
2. Fit the supplied pipe clips (O) in fixed positions, press the unit into the pipe clips and tighten the
three-part coupling (I). Pay hereby attention to the correct position of the sealing rings (P), both
with regard to the connections and the quartz glass.
3. (* Only for 130W Amalgam) The glued socket for the flow switch (V) must be glued onto the
three-part coupling (I) with the screw thread (W) pointing upwards. You can glue the glued
socket (V) to the bottom three-part coupling (I). Fit the flow switch (X), which is attached to
the electronic pre-selector, perpendicular to the screw thread (W) of the glued socket (V). The
device will not work if the flow switch is mounted differently. The arrow on top of the flow
switch (X) must always point in the direction in which the water is flowing. The Blue Lagoon
UV-C Amalgam will not switch on if the flow switch is pointing in the opposite direction (against
the flow of the water).
4. Fit the unit into the circuit using the three-part couplings (I). The inlet and outlet of the three-
part coupling is O 63 mm. If your pipes are smaller than 63 mm, you can use the adapter (O 63
x O 50 mm) (T). This must be glued onto the three-part coupling (I). On one side of the adapter
(T), there is a screw thread on the inside giving the option of fitting an adapter, with a sealing
ring (not included in the delivery), onto it if necessary. Adapter tails can be obtained from your
point of sales.
5. Unscrew the screw ring (N) from the housing (U). Remove the UV-C lamp (K) from the supplied
case (see packaging) and carefully slide the lamp into the quartz glass (M). Carefully connect the
fitting (L) to the UV-C lamp (K) and then screw the screw ring (N) handtight onto the housing (U).
6. Activate the pump and check the flow and any leakage of the system.
7. Put the plug of the UV-C device in a wall socket with a safety ground and fitted with a residual
current circuit-breaker. Check whether the lamp is operating by looking through the transparent
components of the unit. The unit is switched off by pulling the plug out of the socket.
INSTRUCTIONS FOR USE OF THE DIGITAL TIME METER
As soon as the Blue Lagoon UV-C Timer is switched on, the program will carry out a self-test. The
display will automatically show the following , one after the other: 8888 (display test); r and software
version number; 50H or 60H indication of the mains frequency Following this, the display will show
the meter reading.
When the UVC lamp is switched on for the first time, or after the "reset" function has been used, the
value '9000' will appear on the display. A dot next to the digit on the far right of the display will blink
every second; this indicates that the counter is running.
The display is automatically set to the factory reading of 9000 hours. The UV-C lamp operates
radiation for up to 9000 hours. After 9000 hours, the radiation will weaken, and may become
insufficient to obtain the desired results.
If the UV-C lamp had already been used previously, and is switched on again, the display will
6
| BLUE LAGOON UV-C TIMER 40W, 75W & 130W AMALGAM

Publicidad

Tabla de contenido
loading

Tabla de contenido