The time meter will indicate in the following manner that the lamp must be replaced:
EN
•
From hour position 0672; the display will blink every second. The lamp is to be replaced in 4
weeks' time.
•
From hour position 0336; the display will blink every half second; The lamp is to be replaced in
2 weeks' time.
•
From hour position 0168; the display will blink every . second; The lamp is to be replaced in 1
week's time.
•
At an hour position of 0000; the digits will blink continuously, and the meter will not continue to
count down. The lamp must be replaced.
DISMANTLING / MAINTENANCE
Always switch off the power and water supply during maintenance/dismantling of the device.
The device must be cleaned at least twice a year. If there is an increase in pollution and/or scale, the quartz
glass tube (M) in which the lamp is positioned must be cleaned. The special lamp must be replaced at the
latest after 9,000 operating hours. The stainless steel interior can be cleaned with a soft brush.
1. Unscrew the three-part couplings (I) and drain the water from the device.
2. Unscrew the screw cap (N) and disconnect the lamp (K) from the fitting (L). Remove the lamp
from the quartz glass and, if necessary, replace the special lamp (K). As these parts are very
fragile, caution is essential.
3. Carefully remove the quartz glass (M) using a large, flat screwdriver (see drawing 3). Never use force!
4. Clean the quartz glass with a suitable agent. Always use a soft cloth to clean the glass in order to
prevent scratches.
5. Pay attention to the correct position of the 3 sealing rings (P) when replacing the quartz glass in
the housing, and carefully introduce the end of the quartz glass into the inlet(Q) (see drawing 4).
Never use force!
6. Carefully replace the lamp in the quartz glass and connect the lamp (K) to the fitting (L). Screw
the screw cap (N) onto the housing again.
7. The electrical unit of the device is situated in the display box (S) on the device. This display box
is glued and cannot be opened. If the electrical unit or the display is replaced, the entire box
must be unscrewed and the wiring must be disconnected from the device (see drawing 1).
Unscrew the screw top (N) and carefully remove the lamp holder from the lamp. Any loose
parts, i.e. of the earth etc., must be carefully retained, as they are not supplied with a new
housing or electrical unit. In case of any doubt with regard to the connection, consult a
recognized fitter.
8. If the housing needs replacing, the earth (J) and the electrical unit with the display (S) must first
be disconnected from the housing (U) (see drawings 1 & 2). Unscrew the electrical unit with
display (S) and the lamp holder from the housing. Be sure to carefully retain the various loose
parts of the earth, as they are not supplied with a new housing. Remove the lamp (K) and quartz
glass (M) from the housing in order to prevent breakage during transport. In case of any doubt
with regard to the connection, consult a recognized fitter.
8