Maintenance
7 .2 Setting the tension force via the adjustment dial
The tension force is selected in N (Newton) using the tension force scale.
Setting (tension force
scale)
Tension force
MK9SST in
f Turn the adjustment dial for the quick adjustment
force scale
(Figure
1
• For the tension force range 1-4, turn the lever to Standard (STD).
• For the tension force range 5-8, turn the lever to Heavy (HVY).
f Use the adjustment dial of the fine adjustment
tension force scale
The specified tension forces are only general reference values. Due to the diversity of possible
influences during processing and use, we recommend checking the tension cut off forces with a
conventional force meter.
7 .3 Locking of the fine adjustment
The adjustment lock prevents unintentional adjustment of the tension force.
f Remove the screw
f Screw in the screw
7 .4 Locking of the quick adjustment
f Tighten the screw for the tension force lock
the scope of delivery).
8 Maintenance
The application tool is largely maintenance-free.
9 Repairs
NOTE
The application tool can be damaged when opening the housing, making changes to the components or if
repairs are carried out incorrectly.
f Application tool only to be repaired by authorised personnel.
Repair work must only be carried out by the manufacturer or persons authorised by the
manufacturer. This also includes opening the application tool and changing components or
functions.
6
1
2
271
341
).
J
(Figure
).
1
H
(Figure
) from the adjustment dial
2
C
(Figure
) in the marked hole "LOCK"
2
D
Operating Instructions • MK9SST • 02-2016 • 110-95000
3
4
5
421
491
570
(Figure
) to the desired range on the tension
1
I
(Figure
) to set the precise desired value on the
1
G
with a screwdriver.
1
.
1
(Figure
) with an hex socket wrench (included in
3
A
6
7
8
660
715
776