Contents of packaging
6 VELUX
®
Product overview
Default settings
Product overview
1 Light-emitting diode
2 ETHERNET/service
3 Power supply
4 Key button
5 RESET
6 Outputs
7 Inputs
Default settings
Inputs (control)
An external control signal shorter than 1.5 seconds makes the VELUX
product travel to end position.
• Even inputs (2, 4, 6, 8) are used for close/down: The product travels to
• Odd inputs (1, 3, 5, 7) are used for open/up: The product travels to end
An external control signal longer than 1.5 seconds makes the VELUX
products travel until the signal stops or until the product has reached end
position.
Default speed is used for all skylight operators including those supporting
silent mode.
As default, io-homecontrol
channels or signals are blocked.
Outputs (signals)
The output relay is activated for 2 seconds when an action has been suc-
cessfully executed.
The default settings can be adjusted by using the web interface.
See enclosed supplementary instructions