WARNING
2. OPERATION
Wear safety glasses or goggles. Danger to the
eyes always exists due to the possibility of dust
being blown up by the exhausted air or of a fas-
tener flying up due to the improper handling of
the tool. For these reasons, safety glasses or
goggles shall always be worn when operating
the tool.
The employer and/or user must ensure that
proper eye protection is worn. Eye protection
equipment must conform to the requirements of
Council Directive 89/686/EEC of 21 DEC. 1989
(the American National Standards Institute,
ANSI Z87.1) and provide both frontal and side
protection.
The employer is responsible to enforce the use
of eye protection equipment by the tool operator
and all other personnel in the work area.
NOTE: Non-side shielded spectacles and face
shields alone do not provide adequate protection.
WARNING
Keep hands and body away from the discharge
outlet when driving the fasteners because of
dangerous of hitting the hands or body by mis-
take.
WARNING
NAIL LOADING
• When loading the nails, be sure to release
the finger from the Trigger.
• Do not press the Contact Arm against the
object.
PROCEDURE
1 Load the nails into the slot in the rear of the
Magazine until they go over the Nail Stopper.
2 Pull the Pusher as far as the rear end of the
magazine and release it gently.
CAUTION
Abrupt release of the Pusher causes jamming
of nails or dry-firing.

TEST OPERATION

1 Adjust the air pressure at 17 bar (250 p.s.i.)
and connect the air supply.
2 Without touching the trigger, depress the
contact arm against the work-piece.
Pull the trigger. (The tool must fire the fas-
tener.)
3 With the tool off the work-piece, pull the trig-
ger.
10
Nail Stopper
Nails
Pusher