5 Threaded ring for fastening the tube...
6 Toothed rod
7 Rod knob
8 Trigger switch for switching the device on and
off
9 Adjusting wheel for setting feed rate
10 Battery pack release button
11 Battery pack *
12 Capacity indicator button *
13 Capacity and signal indicator *
14 Plastic bag *
15 Extruder plate for plastic bags
16 Extruder plate for cartridges
17 Cartridge *
* not part of the delivery scope / depends on design
variant
6. Initial Operation
6.1
Battery pack
Charge the battery pack before use.
Recharge the battery pack if performance
diminishes.
Instructions on charging the battery pack can be
found in the operating instructions of the Metabo
charger.
Removal: Press the battery pack release button
(10) and remove battery pack (11).
Fitting: Slide in the battery pack (11) until it
engages .
Li-Ion battery packs "Li-Power, LiHD" have a
capacity and signal indicator (13):
- Press the button (12), the LEDs indicate the
charge level.
- The battery pack is almost flat and must be
recharged if one LED is flashing.
6.2
Fitting plastic bags
- Unscrew the front cap (1) from the tube (3).
- Push the rod knob (7) until the stop - this grants
access to the extruder plate (16).
Mount the extruder plate for plastic bags
(15) as shown ! See page 2, fig. A.
- Snip the top of the nozzle (2) as required for the
work to be carried out.
- Pull the rack knob (7) back as far as the stop.
- Push the plastic bag (14) inside the tube (3).
- Trim the plastic bag (14) as recommended by the
plastic bag manufacturer.
- Insert the nozzle (2) in the front cap (1) and secure
the front cap (1).
- Now gently press the rod knob (7) to advance the
toothed rod until it comes in contact with the
plastic bag.
6.3
Fitting the cartridge
- Unscrew the front cap (1) from the tube (3).
- Push the rod knob (7) until the stop - this grants
access to the extruder plate (16).
Remove the extruder plate for plastic bags
(15) as shown ! See page 2, fig. B.
- Open the cartridge (17) as per the cartridge
manufacturer's instructions.
- Snip the top of the cartridge nozzle as required for
the work to be carried out.
- Pull the rack knob (7) back as far as the stop.
- Push the cartridge (17) with the attached cartridge
nozzle into the tube (3) and secure the front cap
(1),
or
Insert the cartridge (17) with attached cartridge
nozzle into the half shell (4) (depends on design
variant / not part of the delivery scope).
- Now gently press the rod knob (7) to advance the
toothed rod until it comes in contact with the
cartridge.
7. Use
7.1
Multifunctional monitoring system
If the device switches off automatically, the
machine electronics have activated automatic
protection mode.
Causes and remedies:
1. Battery pack almost flat (the electronics
prevent the battery pack from discharging totally
and avoid irreparable damage).
If the battery pack is almost flat, it must be
recharged.
2. Long continuous overloading of the machine will
activate the temperature cut-out.
Leave the machine or battery pack to cool.
3. If the current is too high (for example, during
extended periods of overloading) the device is
switched off.
Using the trigger switch, turn off the device (8)
and remove the battery pack. Determine the
cause of the problem and resolve it.
7.2
Setting the feed rate
Set the feed rate using the adjusting wheel (9).
7.3
Switching on and off
Switching on: press the trigger switch (8).
Switching off: release the trigger switch (8). Note:
The toothed rod is automatically retracted slightly to
avoid dripping.
However, if you activate the trigger switch at brief
intervals (shorter than 1 second), the rod is not
automatically retracted. This allows precise dosage
of volumes.
Note: The motor switches off automatically if either
the cartridge or the plastic bag is empty.
8. Accessories
Use only original Metabo or CAS (Cordless Alliance
System) battery packs and accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating
instructions.
Batter chargers: ASC ultra, SC 30, etc.
ENGLISH en
9