Descargar Imprimir esta página

Sears Kenmore 106.8955 Manual De Uso Y Cuidado página 8

Fabrica de hielo

Publicidad

Idiomas disponibles

Idiomas disponibles

Water
Supply Line
Drain Tube
A. _ "copper
tubing
B. Cable
clamp
C. _ "compression
nut
A
.......... _ C
E
D. Ferrule
(sleeve)
E. Ice maker
connection
Drain Pump Installation
NOTE: Do not kink, smash or damage tubes or wires during
installation.
1.
2.
Unplug
ice maker
or disconnect
power.
Remove
rear
panel.
See "Rear
Panel"
illustration
for 5 screw
locations.
Pull rear panel
away
from
the drain
tube
and
discard.
Rear Panel
A
A. _" adjustable
hose clamp
C. _" adjustable
hose clamp
B. Drain tube (ice bin to drain pump)
D. Drain pump reservoir
inlet
Install vent tube
(5/16"
ID x 32" [81 cm]) to drain pump
reservoir vent. Use one 5/8" small adjustable
clamp, supplied.
See "Parts Locations" illustration.
NOTE: Do not install household drain tube at this time.
Parts Locations
A
A. Screw
locations
Remove the old drain tube and clamp attached to the ice
maker bin.
NOTE: Discard old drain tube and clamp.
Install new drain tube (5/8" ID x 51/8") from ice maker bin to
drain pump reservoir inlet using new adjustable
clamps. See
"Drain Tube" illustration.
NOTES:
Do not kink.
Trim tube
length,
if required.
G
F
A. Vent
tube
B. 5_ ,, hose clamp
C. Drain
pump
discharge
tube
D. Drain
pump
E. ice maker
unit power
cord
F. _8-32
x 3_ "pump
mounting
screws
G. Drain
pump
power
cord t clamp
and
screw
7.
Remove power cord clamp and ground screw attached
to
ice maker power cord, which is mounted to the unit base.
See "Parts Locations" illustration.
NOTE: Clamp and screw will be reused.
Slide drain pump into the ice maker base on the right side.
The pump mounting tab should slip into the rectangular
slot
in the ice maker base. It will be necessary to tip the pump
slightly to slip into the slot. See "Drain Pump Mounting Tab
Slot" illustration.

Publicidad

loading

Este manual también es adecuado para:

Kenmore 106.8959