Charging the battery

Starting charging

1.
2.
3.
4.
5.
6.
Important! If the battery voltage is < 1.0 V, the battery will not be automatically detected.
Charging must be started manually:
Starting charging
1.
manually (deep-
discharge batte-
ry)
CAUTION! Risk of damage when attempting to charge a faulty battery. Before
charging, ensure that the battery to be charged is fully functional.
Select battery type and corresponding operating mode
„Wet" mode
„Refresh wet" mode
CAUTION! Danger of damage to the in-car electronics by refresh charging.
Before beginning refresh charging, disconnect battery from vehicle power
supply.
Set the capacity of the battery to be loaded.
Connect (+) charging terminal to positive pole on battery
Connect (-) charging terminal to negative pole on the battery, or to vehicle body (e.g.
engine block) in the case of vehicle electrical systems.
Charger detects that the battery is connected and starts charging
Once the charging terminals are connected, press start/stop button for approx. 5
secs
WARNING! Risk of serious damage as a result of incorrectly connected char-
ging terminals. The reversal polarity protection facility is inoperative if charging
is started manually (battery voltage < 1.0 V). Connect charging terminals to
correct poles and ensure proper electrical connection to vehicle terminals.
„GEL" mode