6

Commissioning

WARNING
Unauthorised voltage or frequency!
Risk of accidents
► Observe the specifications on the ma­
chine's name plate.
► Observe country-specific regulations.
6.1
Initial commissioning
► Insert the filter/disposal bag [2].
► Fit the cord holder [3].
► Connect the suction hose [3].
6.2
Connecting the mobile dust extractor
WARNING
Risk of injury from uncontrolled tool start-
up
► Before switching on ensure that the con­
nected tool is switched off.
WARNING
Risk of injury from electric current
► Insert the mains plug into an earthed sock­
et.
► Do not reach into the electrical outlet mod­
ule on the mobile dust extractor.
While the mobile dust extractor is
connected to the mains socket, an
electric current is running through
electrical outlet module on the mobile
dust extractor at all times.
Connecting the mobile dust extractor to a
mains socket
The mobile dust extractor is switched off.
► Connect the power cable to a mains socket.
The electrical outlet module [1-2] is live.
Switching the mobile dust extractor to standby
mode
► Press the on/off switch[1-11].
The electrical outlet module [1-2] is live.
The green LED [1-18] indicates
standby mode.
Starting the mobile dust extractor automati­
cally
The mobile dust extractor is in standby mode.
► To start the mobile dust extractor automati­
cally: Switch on the connected tool.
16
Starting the mobile dust extractor manually
The mobile dust extractor is in standby mode.
► Press the MAN button [1-17].
Pull the mains plug from the socket when
you are not using the mobile dust extrac­
tor and before performing any cleaning and
maintenance work.
6.3

Connecting a power tool

WARNING
Risk of injury
► Observe the maximum electrical outlet
module connected load (see chapter
"Technical data").
► Switch off the power tool.
Connecting a mains-powered power tool to the
mobile dust extractor
► Connect the power tool to the electric outlet
module [1-2].
The power tool is connected the to mobile dust
extractor via the power cable.
Connecting a battery-powered power tool to
the mobile dust extractor (MINI I / MIDI I)
► In standby mode, press the connection but­
ton [1-20].
The connection display [1-19] flashes slow­
ly. For a period of 60 seconds, the mobile
dust extractor is ready for connection.
► Turn on the battery-powered power tool.
The mobile dust extractor starts up and the
battery-powered power tool is connected
until the mobile dust extractor is manually
switched off or the mains plug is disconnec­
ted. The battery-powered tool must then be
connected again.
Connecting a new battery-powered power tool
overwrites the previous connection.
6.4
Connecting a mobile device (MINI I /
MIDI I)
A mobile device (e.g. smartphone) can be con­
nected to the mobile dust extractor via Blue­
tooth
®
(e.g. for a software update with the Fes­
tool app).
► Hold down the connection button [1-20] on
the mobile dust extractor for three seconds
in standby mode.
The connection display [1-19] flashes rapid­
ly.
For a period of 60 seconds, the mobile dust
extractor is ready for connection.