TEC29 EV, TEC29 EV LPG
8.7
Checking the oil level
!
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
I
NOTE
The generator must be level.
Always check the oil level before use. To do this, proceed as follows:
➤ Open the generator front door.
➤ Switch the generator to no function with the main switch (fig. 4 1, page 5).
➤ Disconnect the positive terminal of the supply battery.
➤ Take the dipstick (fig. 4 2, page 5) out of the filler neck (fig. 4 3, page 5).
➤ Clean the dipstick (fig. 4 2, page 5) with a cloth.
➤ Put the dipstick (fig. 4 2, page 5) back into the filler neck (fig. 4 3, page 5).
➤ Take the dipstick (fig. 4 2, page 5) out of the filler neck.
➤ Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick (fig. 4 4, page 5).
If not, top up with more oil.
➤ Put the dipstick (fig. 4 2, page 5) back into the filler neck (fig. 4 3, page 5).
➤ Check that the oil level is not above the maximum level.
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. 4 1, page 5).
➤ Close the generator front door.
EN
Operating the generator
21