Connecting Devices; Ac Operation - Zipper Maschinen ZI-STE3000L Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

17.2

Connecting devices

Before connecting a device on the AC socket you must control the perfect condi-
tion of the device.
When you recognise that a connected device acts unusual you must stop the
generator and disconnect the device. Control whether the device is damaged or
if the generator was overchallenged by the device.
ATTENTION: A short exceed of the normed power capacity of the generator is possi-
ble but if this happens oftener the life time of the generator will be shortened.
In exceptions the generator can be charged with the maximum power for max. 30
minutes.
The following list gives you a view about the differences of the electricity requirement
of some devices between start and continuous operation.
Verbrauchsart
Expenditure
of watt
Start
Electrical equip-
X1
ment
Light
X1,5
Devices with
X
engines
3~5
Please consider: Some devices, for instance cooling devices need up to 5 times more starting
current than current during the operation.
17.3

AC Operation

Connect the devices to the AC socket. The most devices need more energy (VA) for
starting than declared. A device with a normed power requirement of 1500 VA might
charge your generator up to its maximum for a short time.
.
Z.I.P.P.E.R Maschinen Austria
Instance type of
device
During
opera-
tion
X1
X1
X2
www.Zipper-maschinen.at
OPERATION INSTRUCTIONS
Instance
device
Start
100VA
80VA
450-
750VA
Stromerzeuger / Generator ZI-STE3000L
During
operation
100VA
60VA
300VA
Seite 37

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido