Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 41)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Fault
SatinFlow too low / little water
Changeover to SatinFlow is stuck
Mixer dripping
To little water at the pull-out spout
Water escaping at the threaded
base
Pull-out length hose too short (less
than 500 mm)
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Nozzles and / or flow restrictor
fouled / calcified
- Changeover button fouled
- Cartridge defective
- Backflow preventer in the hose
connection and faucet aerator
calcified / fouled
- connection hoses not completely
screwed into basic body
- Hose weight assembled in wrong
position
Assembly (see page 33)
English
Maintenance (see page 56)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 42)
Flow diagram (see page 42)
Spare parts (see page 48)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
800 = Stainless Steel Optic
Special accessories (order as an extra)
extension #43333000 (see page 47)
Cleaning (see page 56)
Operation (see page 50)
Hansgrohe recommends not to use as drinking water
65°C
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate (see page 50)
Remedy
- Dismantle and clean nozzles and
flow restrictor.
- Detach and clean changeover
button
- Exchange cartridge
- Clean backflow preventer and
faucet aerator
- Tighten connection hoses by hand
- Assemble hose weight according
to the assembly instructions