9. OPERATION
1. Plug mains power cord from the faze machine
into appropriate power supply socket;
2. "Version 1.0" Primary power on;
3. "Warming Up" 2 seconds after, switches to
working status: heating up;
4. Wait about 60 seconds for heating element to
heat up;
5. "DMX Address:1 _IDLE_" After heating up, dis-
plays the previous functions list before the last
power off: The picture shows the new machine
default state;
6. After the heating up is complete, Please do
follow the required operating modes;
Continuous Fogging Operation
Panel control, DMX signal is not connected.
1. "DMX Address: 1 Vol: xxx Fan: xxx" Press START/
STOP to enter continuous fogging status,
please note continuous fogging starts at the
same moment; The first line is the setting state,
usually shows the last setting in the last opera-
tion, such as DMX, Address, or Volume, or Fan,
Power, and so on, the following will be replaced
by XXXXX. The second line shows the real-time
working state. Under this status, press "ENTER"
to start fogging;
2. Press MENU to enter Volume adjustment;
3. "Volume: 5 _IDLE_" Press "Up" or "Down" to
adjust smoke volume value (5 -100%);
4. Press MENU to switch to adjust the speed of
fan, please note continuous fogging still works
at the same moment;
5. "Fan Power: 5 _IDLE_" Press "Up" or "Down"
to adjust fan speed (5 -100%), press MENU to
switch Volume and Fan Power; Under fogging
status, press " ENTER" to stop fogging;
6. "_IDLE_" Press again START/STOP to stop
Continuous fogging. Please note the machine
design of machine stops working after a delay
of 30 seconds, automatically clear the tubing
of the remaining liquid, at this point, IDLE will
blink;
7. "IDLE" After the Self-cleaning process is com-
plete, IDLE will stop blinking.
When executing continuous fogging, interval value
must be zero, if the interval value change to 5-250
will automatically be converted to timing fogging.
Timing Fogging Operation
Panel control, DMX signal is not connected.
1. "Vol=xxx Fan=xxx" Under this status, press
MENU to get into timing setting, please note
timing fogging stops at the same moment;
The first line is the setting state, usually shows
the last setting in the last operation, such
as DMX, Address, or Volume, or Fan, Power,
and so on, the following will be replaced by
XXXXX. The second line shows the real-time
working state.
2. Press MENU to enter to Interval;
3. "Interval: 6s _ IDLE _" Press "Up" or "Down" to
adjust the value of interval (0s or 5s - 250s)
4. Press again MENU to switch to adjust the
value of duration, please note timing fogging
still stops at the same moment;
5. "Duration: 6s _ IDLE _" Press "Up" or "Down"
to adjust time value of duration (5s - 250s);
6. "Vxxx Fxxx Ixxx Dxxx" After setting the inter-
val and
duration, press START/STOP to
start timing fogging, the main display infor-
mation as shown on the left; Press "ENTER" to
start timing fogging;
7. And so on, you could adjust the volume and
fan speed;
8. "_ IDLE _" Press again START/STOP to stop
Timing fogging. Please note the machine
design of machine stops working after a delay
P. 11
English version
- Neo Steam F1400