Emergency Information; Product Description; Technical Data - Abicor Binzel ABIPLAS WELD CT Serie Manual De Instrucciones

Antorcha de soldadura
Ocultar thumbs Ver también para ABIPLAS WELD CT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIPLAS
WELD CT

2.5 Emergency information

In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
• Coolant supply
• Gas supply
Further measures can be found in the power source operating instructions or the documents for
further peripheral devices.

3 Product description

WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
• Only qualified personnel are permitted to perform work on the device or system.
NOTICE
• The torch body, cable assembly and complete bracket together form an entity.
 6.4 Attaching the torch body to the complete bracket on page EN-14

3.1 Technical data

Welding
Transport and storage
Relative humidity
Tab. 1
Ambient conditions during operation
®
Type ABIPLAS
WELD
Type of use
DC polarity of the electrodes
Voltage rating
Max. arc inflammability and stabilisation
voltage
Breakdown voltage 50 Hz
Protection type of the device connections
(EN 60529)
Tab. 2
Product-specific torch data (EN 60974-7)
BAL.0128 • 2019-09-04
−10 °C to +40 °C
−25 °C to +55 °C
Up to 90 % at 20 °C
150 CT20
Automatic
Usually positive
Peak value of 141 V
4.5 kV
3 Product description
250 CT20
IP2X
EN - 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abiplas weld 150 ct20Abiplas weld 250 ct20

Tabla de contenido