Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1
Make sure the Brush Deck is in the RAISED position. Make sure the Key Switch (A) is off (O).
2
See Figure 2. To access the brushes loosen the black knobs (one on each side) on top of the Idler Assemblies (9) and remove the idler
assemblies. Slide the brush into the housing, lift slightly, push and turn until it seats. Re-install the idler assemblies.
FILLING THE SOLUTION TANK
Fill the solution tank with a maximum of 20 gallons (76 Liters) of cleaning solution. Do not fi ll the solution tank above 7.5 cm (3 inches) from the
bottom of the Solution Fill (1). Use the Solution Level Indicator (22) to monitor the solution level while fi lling. The solution should be a mixture of
water and the proper cleaning chemical for the job. Always follow the dilution instructions on the chemical container label. NOTE: Machines can
either be used conventionally with detergent mixed in the solution tank or the AXP detergent dispensing system can be used. When using the
AXP detergent dispensing do not mix detergent in the tank, plain water should be used. If the pump is not pumping water, there may be air in
the line and it may not be properly priming. This can be corrected by making sure the solution tank is fi lled at minimum to the 20 gallon
level to start out.
CAUTION!
Use low-sudsing, non-fl ammable liquid detergents designed for machine application. Water temperature should not exceed 130