Maintenance And Cleaning; Guarantee Conditions - Pontec PonDuett 3000 Instrucciones De Uso

Ocultar thumbs Ver también para PonDuett 3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
- EN -

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Note!
Recommendation on regular cleaning:
• Clean the pump as required but at least twice a year.
• Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Cleaning the unit
Unscrew the nozzle tube or stepped hose adapter with O ring 12x4 from the connection thread (A), open the engage-
ment hooks on both sides of the filter housing and remove the top strainer casing (B). Take the pump out of the top
foam filter, remove the foam filters, the gravel bags and the biosurface elements from the bottom strainer casing (C).
Unscrew the pump lid or the pump housing (D) and remove the impeller. Clean the impeller (E) and strainer casings
using clear water and a brush, rinse the foam filters, gravel bags and biosurface elements under running water. After
cleaning, fit the unit in the reverse order.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Wearing parts
Foam filters and impeller are wearing parts and are, therefore, not covered by our warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Malfunctions
Malfunction
The unit is not operating
Insufficient delivery rate
Unit switches off after a short running period

Guarantee conditions

PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer's claims against the dealer.
8
Cause
No mains voltage
Impeller blocked
Strainer casing clogged
Foam filter clogged
Water temperature too high
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Clean foam filter
Note maximum water temperature of +35°C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ponduett 5000

Tabla de contenido