The setting "COOL" can be used when a fan is to be used for cooling at high temperatures instead of a heater.
But then the cable may not be too strong (max. 10 W per 100 liters), so only a slight flow of the under gravel is
ensured without significant heating of the water.
Then, you press the "SET" button shortly,
By briefly pressing the "SET" button, there will be access to adjust the temperature difference between the
setpoint and emergency shutdown of the heating cable at an excessively high water temperature. If the setpoint
plus this set value is reached, the heating cable is switched off until the temperature in the aquarium has dropped
again below the setpoint.
By pressing the "SET" button again, you can set the alarm. When reaching the setpoint plus the adjusted value,
you will hear a beep.
socket No. 1 and switches the consumer (heating) on. The heating cable is controlled by the timer and power
socket No. 2.
If you keep pressing the "SET" button for a quite a while, you will reach the timer menu. Here, you can set the
time also by pressing the "SET" button and the arrow keys. Then, the time how long the heating cable should be
turned on and switched off has to be adjusted. A mode of 15 minutes each have been proved suitable. Again, the
value to be changed is selected and then adjusted using the arrow keys by pressing the "SET" button.
By pressing the OK button you can leave the setting menu.
The heat controller duo has got a rechargeable battery so the programmed data will not be lost in
case of power failure. After starting the unit up, it takes about 24 hours until the battery is charged
and the data remain stored.
For safety reasons, you should control the nominal values, especially after a power failure.
5. Technical Data
Display:
Measurement range:
Resolution:
Loading capacity of contact:
Air Humidity:
Adjustment range:
Adjustment accuracy:
Power requirements:
Humidity:
6. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period, we
will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of a
fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
the
As soon as the temperature falls below the adjusted value, the unit activates the power
0.1 °C
0.0 up to +50.0 °C
0.1 °C
1,200 watts at 220 V AC
below 80%
16 – 40 °C
+/- 1 °C
220 V / 50 Hz
< 85%
- Technical changes reserved – 03/2019
setpoint appears flashing and can be changed with the arrow keys.