EN
maximum tolerable level for the skin type. A feeling of heat can be felt on
the skin during the treatment, and this is normal. If discomfort is felt, the
maximum tolerable power level is the previous one.
Check the area after 24 hours: if the redness persists, the maximum
tolerable power level for your skin type is the previous one.
Even though it is extremely rare, if hypersensitivity should persist for over
hours, it is recommended to consult a doctor.
ATTENTION: the power output directly affects the result, however, due to the
principle of heat of the treatment, the maximum limit tolerated by your skin must
not be exceeded. This limit is normally high for fair skin and low for dark skin
because melanin that darkens the skin increases the production of heat. Do not
exceed the maximum limit that your skin tolerates with no discomfort whatsoever.
pREpARING THE AREAS THAT ARE TO BE TREATED
The skin must be shaved, clean, dry, with no make-up, anti-perspirant
or deodorant.
On the face, if the dark hair to treat is sparse and there is little of it, you don't
need to shave the area; simply trim the hair with scissors. If the hair is very
short (about 1mm) and not too thick, you don't need to shave or trim them.
Moles, birthmarks, dark spots, tattoos and lips must be covered with a
white pencil or white patches.
ATTENTION:
Before starting the treatment, read the paragraphs relative to safety warnings,
contraindications, precautions for safe use, possible side effects, treatment
areas and hair removal program.
80

pREpARING THE AppLIANCE

1.
Remove the handpiece and the other components from the package.
2.
Verify that the lamp (6) is inserted correctly into the appliance.
3.
If the appliance is stored in a very cold place, wait for it to reach at least 15°C.
4.
If the plug has not been inserted into the adaptor (15),
hold the latter, pull the "Open" key downwards and
insert the plug (15A, 15B or 15C), which is suitable for
the socket of the electrical system, into the relative slot.
5.
Insert the adaptor cable (15) into the power supply
connection (5).
6.
Insert the adaptor (15) in a socket: the stand-by LED lights up (10).
TREATMENT
7.
Press the switch-on/stand-by button (11): the switch-on LED (12) lights
up and the ventilation system is activated (the noise is similar to that of
a hair dryer).
8.
About 3.5 seconds after having pressed the switch-on/stand-by button
(11), the switch-on LED (12) lights up: the appliance is automatically set
to the lowest power level.
9.
Set the lowest power level when applying the first treatment. Follow the
instructions in the "Information before use" chapter if you wish to use a
different power level for follow-up sessions.
10. Apply the treatment surface (6A or 16A) firmly on the skin. Only when
the treatment surface (6A or 16A) is entirely in contact with the skin, the
ready-for-use LEDs (7) start to flash.