BTL7-A/C/E/G501-M _ _ _ _ -P-S32/S115/KA _ _
Magnetostrictive Linear Position Sensor – Profile Style
1
Notes to the user
1.1
Validity
This guide describes the construction, function and setup
options for the BTL magnetostrictive linear position sensor
with analog interface. It applies to types
BTL7-A/C/E/G501-M _ _ _ _ -P-S32/S115/KA _ _ (see
Type code on page 22).
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the BTL.
1.2
Symbols and conventions
Individual handling instructions are indicated by a
preceding triangle.
► Handling instruction 1
Handling sequences are numbered consecutively:
1. Handling instruction 1
2. Handling instruction 2
Note, tip
This symbol indicates general notes.
Symbols of this type indicate the LED displays.
1.3
Scope of delivery
–
BTL
–
Mounting clamps with insulating sleeves and screws
–
Condensed guide
The magnets are available in various models
and must be ordered separately.
www.balluff.com
1.4
Approvals and markings
US Patent 5 923 164
The US patent was awarded in connection with this
product.
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
The BTL meets the requirements of the following product
standard:
–
EN 61326-2-3 (noise immunity and emission)
Emission tests:
–
RF emission
EN 55011
Noise immunity tests:
–
Static electricity (ESD)
EN 61000-4-2
–
Electromagnetic fields (RFI)
EN 61000-4-3
–
Electrical fast transients (burst)
EN 61000-4-4
–
Surge
EN 61000-4-5
–
Conducted interference induced by
high-frequency fields
EN 61000-4-6
–
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
english
5