Value Table For Factory Setting; Btl7 Configuration Tool; Connecting The Usb Communication Box - Balluff BTL7 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL7 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL7-A/C/E/G501-M _ _ _ _ -P-S32/S115/KA _ _
Magnetostrictive Linear Position Sensor – Profile Style
6
Configuration with the BTL7 Configuration Tool
6.1

Value table for factory setting

Output gradient
Rising
BTL7-A...
(output 1)
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
(output 2)
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for factory settings
NOTICE!
Interference in function
Configuration with the BTL7 Configuration Tool while the
system is running may result in malfunctions.
► Stop the system before configuration.
6.2

BTL7 Configuration Tool

The BTL can be quickly and easily configured on the PC
using the PC software BTL7 Configuration Tool.
The most important features include:
Online display of the current position of the magnet
Graphical support for setting the functions and curves
Display of information on the connected BTL
Selectable number formats and units for display
Resetting to factory settings is possible
Demo mode without a connected BTL
The PC software and associated
manual can be found in the Internet under
www.balluff.com.
14
english
BTL
Unit
Min. value
V
−0,5
V
−10,5
mA
mA
V
+10,5
V
+10,5
mA
20,4
mA
20,4
Null value
End value
0
+10,0
−10,0
+10,0
0
0
20,0
3,6
4,0
20,0
+10,0
+10,0
−10,0
20,0
20,0
6.3

Connecting the USB communication box

For a BTL with connector the communication box must be
inserted between the BTL and the controller. The
communication box is connected to the PC via a USB
cable.
Connection cable approx. 0.3 m with
S32 or S115 (female) connector
Fig. 6-1:
Connecting the communication box with a connector
For a BTL with cable connection the communication lines
La, Lb and GND are connected to the USB communication
box.
USB cable
Fig. 6-2:
Connecting the communication box with a cable connection
When reading or writing data via the
Configuration Tool, both LEDs flash green.
Max. value
Error value
+10,5
+10,5
+10,5
+10,5
20,4
20,4
20,4
0
−0,5
−0,5
−10,5
−10,5
0
0
20,4
4,0
3,6
Connection cable
USB cable
approx. 0.3 m with
S32 or S115 (male)
connector
8-pin
6-pin
8-pin
Connection cable
approx. 0.6 m with
luster terminal
3,6
3,6
Controller
Controller

Publicidad

Tabla de contenido
loading

Tabla de contenido