English
Maintenance
Always unplug the power cable before
servicing or cleaning the machine.
In order to ensure trouble free operation,
we recommend carrying out the
following steps whenever the machine is
used:
Rinse the water hose, high-
N
pressure hose, spray lance and
accessories with water before fitting
them
Remove all sand and dust from the
N
plug-type coupling of the spray
lance and the coupling sleeve of the
spray gun
Cleaning the high-pressure nozzle
Since the pump pressure increases if
the nozzle is clogged, it must be cleaned
immediately.
Switch off machine
N
Actuate the spray gun until water
N
merely drips from the spray head –
the machine is now depressurized
Remove spray lance
N
Clean nozzle with a suitable needle
N
46
Always remove the spray lance before
cleaning the nozzle.
Rinse spray lance with water from
N
the nozzle end
Cleaning the water intake strainer
The water intake strainer must be
cleaned every week or more often if
necessary.
2
1
Disconnect hose (1)
N
Carefully release the strainer (2)
N
with pliers and rinse it
Before refitting the strainer, ensure
N
that it is undamaged and replace if
necessary
Clean ventilation openings
The machine must be kept clean so that
cooling air can flow freely through the
openings in the machine.
Lubricate connections
Lubricate the connections on the high-
pressure hose as needed
RE 361, RE 361 PLUS, RE 461, RE 461 PLUS, RE 471 PLUS
Checking the machine supports
The two front machine supports must be
replaced if damaged or worn, to ensure
the stability of the machine.