C-Series Power Supply Instruction Manual
Environment
Operational temperature
Storage temperature
Humidity
Vibration sinusoidal
Shock
Allowed output current versus
the ambient temperature
Ambient temperature is defined
2cm below the unit.
Please note:
The CS5 units can respond with a
thermal shut-down when
continuously loaded with more than
120W and operated with a mains
voltage of 100V or below.
Safety
Separation of output
SELV
PELV
Touch current
CS5: <0.7mA
CS10: <0.7mA
Isolation resistance
min. 5MOhm
PE resistance
max. 0.1Ohm
Transformer
Safety transformer
Approvals
See datasheet or markings on the unit
EMC
CS5.243, CS5.244, CS10.242, CS10.243:
These devices are suitable for applications in industrial environment as well as in residential,
commercial and light industry environment without any restrictions.
For further details see datasheet.
EMC Immunity
EN 61000-6-1, EN 61000-6-2
EMC Emission
EN 61000-3-2, EN 61000-3-3, EN 61000-6-3, EN 61000-6-4,
FCC Part 15 Class B
This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
FCC
interference received, including interference that may cause undesired operation.
CE mark is in conformance with EMC guideline 89/336/EEC and 93/68/EEC and the low-voltage directive (LVD) 73/23/EWG.
Physical Dimensions, Weight and
Cooling
Weight
500g / 1.1lb
CS5.xxx
700g / 1.54lb
CS10.241
CS10.243
CS10.244
CS10.481
800g / 1.76lb
CS10.242
DIN-Rail
Use DIN-rails according to EN 60715 or
EN 50022 with a height of 7.5 or 15mm
Mounting Orientation
Output terminal on top and input terminals
on the bottom.
For other orientations see datasheet.
Do not obstruct air flow!
The unit is convection cooled. Ventilation grid must be kept free of any obstructions.
Keep installation clearances at higher ambient temperature and full load:
40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance
are recommended.
PU-360.010.00-10A
-25 to +70°C
De-rate above +60°C
-40 to +85° C
Storage, transport
< 95% r .H.
IEC 60068-2-30
Do not energize while condensation is present
2g
IEC 60068-2-6
30g 6ms, 20g 11ms
IEC 60068-2-27
Allowable Output
Current
120%
100
80
60
4
2
Ambient Temperature
0
-25
0
20
40
IEC/EN 60950-1
EN 60204-1, EN 50178, IEC 60364-4-41
Earth leakages current, TN- mains
Input to output, 500Vdc
Between housing and ground terminal
IEC/EN 61558-2-17
CS5
Protection
Output
Degree of protection
Class of protection
Over-voltage category
Degree of pollution
Over-temperature protection
Output over-voltage protection
Penetration protection
Internal input fuse
(Device protection, not externally
accessible, IEC 60127-2/5, HBC)
External fuse on input side
The unit is tested and approved for branch circuits up to 20A. External protection is only
required if the supplying branch has an ampacity greater than this. In some countries local
regulations might apply. Check also local codes and local requirements. If an external fuse is
necessary or utilized, minimum requirements need to be considered. To avoid a wrong
tripping of the circuit breaker, a minimum value of:
B10A or C6A for CS5.241, CS10.241, CS10.241, CS10.242 and
60
70°C
B16A or C10A for CS5.2413, CS5.244, CS10.243, CS10.244 is required.
Terminals and Connections
Type
Solid wire
Stranded wire
American wire gauge
Ferrules
Stripping length
Screwdriver
Recommended tightening torque
Use appropriate copper cables that are designed for an operating temperatures of 60°C (for
ambient up to 45°C) and 75°C (for ambient up to 60°C), minimum. Follow national installation
codes and regulations! Ensure that all strands of a stranded wire enter the terminal connection!
Up to two stranded wires with the same cross section are permitted in one connection point
(except PE wire). Do not use without PE (Ground) connection!
EMC
CS5.241, CS10.241, CS10.244, CS10.481:
These devices are suitable for applications in industrial environment without any restrictions.
For further details see datasheet.
EMC Immunity
EMC Emission
CS10
Overload, no-load, short-circuit proof
IP 20
EN/IEC 60529
I
PE (Ground) connection required!
III
EN 50178
2
EN 50178, not conductive
yes
Output shut-down with automatic restart
yes
Output shut-down with automatic restart
>3.5mm
e.g. screws, small parts ...
T4A
CS5
T6A3
CS10
Screw Terminals
2
0.5-6mm
2
0.5-4mm
20-10 AWG
allowed, but not required
7mm / 0.275inch
3.5mm slotted or Philips No 2
0.8Nm, 7lb.in
EN 61000-6-1, EN 61000-6-2
EN 61000-3-3, EN 61000-6-4, FCC Part 15 Class B
CS5, CS10