Parameter menu
Standby Temp. (STANDBY)
After activating the Setback function or after pushing the ECO button (WR 2), the temperature is automa-
tically reduced to Standby temperature. The display flashes the actual temperature. STANDBY appears
on the display.
Setback time (SETBACK)
If the soldering tool is not in use, the temperature
is reduced to Standby temperature on expiration of
the preset Setback time.
SETBACK appears on the display.
To exit Standby mode, push the „UP / DOWN"
buttons or ECO (WR 2).
Depending on the tool in use, the finger switch or
the safety rest deactivates Standby mode.
Vacuum pre-feed (VAC On)
In order to prevent the pump from starting pre-
maturely or to ensure a defined soldering-joint
preheating time, it is possible to set an ON delay.
Vacuum run-on (VAC Off)
To prevent the desoldering iron from becoming
clogged, it is possible to set a vacuum run-on time.
(factory setting 2 s)
The on-time of the hot air flow of the HAP 200
can be limited in increments of 1 to between 0
and 60 sec. The set time is then identical for all 3
channels.
The factory default is 0 s („OFF"), i.e. air flows
only as long as the button on the hot air tool or the
optional footswitch is pressed.
Option
Description
OFF
No duration defined
(factory setting)
1-60 s
Individually adjustable
Option
Description
0 sec
OFF: vacuum pre-feed function is
OFF (factory setting)
1- 9 sec
ON: vacuum pre-feed time, indivi-
dually
Option
Description
0 sec
OFF: vacuum run-on function is OFF
(factory setting)
1- 5 sec
ON: vacuum run-on time, individually
adjustable
Menu access
- 1 -
Menu access
- 1 -
Menu access
- 1 -
- 1 -
Menu access
45