The portable lamp must not be opened in the potentially explosive zone!
5.1 Replacement of battery
For that see illustrations on page 26.
. Unscrew 3 Torx screws on the left and right at the housing and on the bottom (5).
2 Draw the back panel of casing (8) from the headlamp casing.
3. Release plug-in cable lugs + and – at the battery (4) (5).
4. Draw out old battery (23) from the cas-ing and push in the new one.
5. Contact the new battery b) with cable connections (4) red = + positive pole and (5) black =
- negative pole.
Do not confound the connections!
6. Close and screw up the casing.
Attention:
a) Take care of a good sealing (protec-tion provided by enclosures)!
Is the sealing still okay?
b) Insert absolutely an original ecom instruments-battery-pack. Other batteries are
not allowed and abolish the explosion proofness!
Remember environmental protection!
Used batteries must be disposed of in accordance with environmental require-ments. If this is
not possible we take them back and have the battery cells recycled correctly and completely, i.e.
potentially pollutive materials are recovered and used for the production of new battery cells.
5.2 Replacement of lamp
For that see illustrations on page 26.
. Release and draw out the red inset (9) at the head of lamp by removing of Torx-screw
*TX0* (8)
2. Main and economy lamp (3) and (2) are easily accessible and be removed by pressing
and rotating.
3. Re-insert lamps and inset (9) in re-versed order.
Attention:
a) Touch new filament lamps only with a protective rag!
b) At the inset (19) take care that the locating studs engage properly at the top of the head
of lamp and that the sealing of the complete part is okay. Do not crush lines in
closing!