The status of the cooler (compressor on or off) is indicated on the small LED in the display (between second and
third digit of the display).
4. Technical data cooling unit
Power (compressor):
Power uptake (watts):
Cooling power (watts):
for aquaria up to:
( T =10 °C)
( T = 5 °C)
Recommended water flow
(litres/h):
Weight:
Cooling gas:
Quantity of coolant:
Dimensions (l x w x h):
Heat exchanger:
Temperature controller:
Available spare parts: Please refer to www.aqua-medic.de.
5. Maintenance
The cooler has the same requirements with respect to maintenance like conventional cooling units (refrigerators
etc.). Maintenance and/or repairs should be done exclusively either by a service engineer or by the
manufacturer. Clean the air-cooled condenser regularly. Beforehand, unplug the unit. Then, open the
housing with a screwdriver and release the fins of the condenser of dust carefully. Without this regular cleaning,
fan and compressor may be irreversibly damaged. We recommend to flush the heat exchanger thoroughly once
a year to remove any muddy parts.
6. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
5
Titan 150
Titan 500
1/10 HP
¼ HP
150 W
190 W
395 W
200 W
100 l
250 l
250 l
500 l
200 – 1,500
500 – 2,000
13.7 kg
14.5 kg
R 134 a
100 g
200 g
35 x 30 x 35 cm
39 x 34 x 39 cm
Titanium
digital, accuracy 0.1 °C, set point adjustion in 1 °C step
- Technical changes reserved – 09/2019/v4
Titan 1500
Titan 2000
½ HP
1 HP
375 W
550 W
790 W
1,650 W
700 l
1,500 l
1,500 l
2,500 l
800 – 2,500
2,000 – 4,000
16.6 kg
31.5 kg
220 g
450 g
40 x 50 x 44 cm