9 Taking out of operation
When used for its intended purpose, the gas hot air blower can be used without time limitation.
Should the tool need to be taken out of service, it must be disposed of correctly in accordance
with the country-specific disposal guidelines.
10 Spare parts and accessories
NOTE
The use of spare parts and accessories not approved by the manufacturer can damage the gas hot air
blower.
f Use only approved spare parts and accessories otherwise warranty claims shall be rendered void.
Spare parts and accessories can be obtained directly from the respective HellermannTyton country
representative.
Spare parts/accessories
P445 refill cartridge (butane, propane, propylene)
11 Technical data
Dimensions
TYPE
(W x H x D)
E4500
260 x 80 x 170 mm
Maximum gas consumption
75 g/h
Operating
Weight
time
approx. 1.5
0.760 kg
hours
Operating temperature
range
to -8°C
Operating instructions • E4500 • 05-2016 • 391-90002
Taking out of operation
Article-No .
391-90101
Generated temperature
range
+ 400-750°C
Ignition type
Piezo ignition
Article-No .
391-90002
7