INSTALLATION, RELOCATION AND INSPECTION
Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
• Where there is high-frequency or wireless equipment.
WARNING :
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will
be generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
WARNING :
•
The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.
•
Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
SPECIFICATIONS
Set name
Model
Indoor
Outdoor
Function
Cooling
Power supply
Capacity
kW
—
Input
kW
—
Indoor
kg
Weight
Outdoor
kg
Refrigerant filling capacity
kg
(R410A)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Indoor (Super High/
dB(A)
Noise level
High/Med./Low)
Outdoor
dB(A)
14
The installation location of the outdoor unit should be at least
3 m away from the antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater space between the
outdoor unit and the antenna of the affected device if operation
of the air conditioner interferes with radio or TV reception.
Inverter-type
To prevent the effects
fluorescent lamp
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent the
picture
100 mm or
1 m
distortion or
more
or more
the noise.
1 m
TV
Cordless
or more
phone or
Portable
3 m
phone
Radio
or more
—
MSZ-CB25VA
MSZ-CB22VA
MSZ-CB25VA
—
MUZ-GA25VA
Heating
Cooling
Heating
Cooling
~ /N, 230V, 50Hz
—
2.5
3.2
3.5
—
0.64
0.76
1.08
9
—
31
—
0.85
IP 20
—
IP 24
1.64
4.15
43/36/29/21
—
46
CAUTION:
• Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is incorrect,
it may cause an electric shock.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
wall, etc.
Inspection and maintenance
Well-
ventilated
dry place
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc.
200 mm or
more
• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.
• If an abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and
work are required.
WARNING :
Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
NOTE:
MSZ-CB35VA
1. Rating condition
MSZ-CB35VA
MUZ-GA35VA
Cooling —
Indoor
Heating
Outdoor : 35°C DB
Heating —
Indoor
4.0
Outdoor : 7°C DB, 6°C WB
1.055
2. Guaranteed operating range
33
0.90
Upper limit
Cooling
Lower limit
Upper limit
Heating
43/36/29/22
Lower limit
47
48
If you have any questions, consult your dealer.
3. CB22 has no specifications for single combination.
: 27°C DB, 19°C WB
This indoor model is only for multi system air conditioner.
As for the specifications of multi system, please confirm
: 20°C DB
your dealer and/or refer to the catalogue.
Indoor
Outdoor
32°C DB
46°C DB
23°C WB
—
21°C DB
-10°C DB
15°C DB
—
27°C DB
24°C DB
—
18°C WB
20°C DB
-10°C DB
—
-11°C WB