KPAW-01
TRUE RMS 1000A AC WATT Clamp Meter
range.
2. Press the lever to open the transformer jaw.
3. Center the conductor within the transformer jaw, then
release the Meter slowly until the trasnformer jaw is
completely closed, Make sure the conductor to be tested is
placed at the center of the transformer jaw, otherwise it will
casue deviation. The Meter can only measure one
conductor at a time, to meausre more than one condutor at
a time will cause deviation.
4. The double display shows the AC current True RMS
value and AC voltage True RMS value.
5. Press MAXMIN, the LCD displays
recording the maximum AC current True RMS value.
6. Press MAXMIN, the LCD displays
the minimum AC current True RMS value. Press MAXMIN,
again to show the present AC current True RMS value.
7. The display shows 0L when the current of the tested
conductor is higher than 1000A rms.
Note
When the measurement has been completed,
disconnect the connection between the conductor under test
and the jaw, and remove the conductor away from the
transformer jaw of the Meter.
C. Active Power (main display) + Phase Angle
(secondary display) Measurement
Warning
To avoid damages to the Meter or harms to you, do you
18
, it starts
, it starts recording
www.grupotemper.com